2.3 CHARGE CORONA CIRCUIT
The main board su24 volts to the CC/Grid/Bias power pack at CN1-1
as the power supply source. After the Start key is pressed, the CPU drops
CN1-3 from +24 volts to 0 volts. This energizes the charge corona circuit
within the CC/Grid/Bias power pack, which applies a high negative voltage of
approximately –5.6 kv to the charge corona wire. The corona wire then
generates a negative corona charge.
The grid limits the charge voltage to ensure that the charge does not fluctuate
and an even charge is applied to the drum surface.
The grid trigger pulse applied to CN1-5 is a pulse width modulated signal
(PWM signal). This signal is not only a trigger signal; it also changes the
voltage level of the grid. As the width of the pulse applied increases, the
voltage of the grid also increases.
VA [24]
VC [5]
GND [0]
Main Board (PCB 1)
CN112-8
CN112-7
CN112-6
CN112-5
CN112-4
CN112-3
CN112-2
CN112-1