T
echnical
B
ulletin
PAGE: 1/2
Reissued: 22-Nov-12
Model: Finisher SR5040/SR5030 (D512/D513)
Date:
20-Jun-11
No.:
RD512001b
RTB Reissue
The items in bold italic have been added.
Subject:
Firmware Release Note: Finisher_COLUMBIA_B
Prepared
by:
T. Komori
From:
1st PP Tech Service Sect., PP Tech Service Dept.
Classification:
Troubleshooting
Mechanical
Paper path
Part information
Electrical
Transmit/receive
Action required
Service manual revision
Retrofit information
Product Safety
Other (Firmware)
Tier 2
This RTB has been issued to announce the firmware release information for the
Finisher.
Version
Program No.
Effective Date
01.050:01
D5125620E
December 2012 production
01.040:01
D5125620D
November 2011 production
01.030:01
D5125620C
1st Mass production
Version
Modified Points or Symptom Corrected
01.050:01
Specification Changed
Change the machine control to improve jam removal for booklet
stapling
01.040:01
Plockmatic and GBC Punch are supported on this combination (Engine,
System/Copy), Fiery ver.1.2 and SR5030/5040 D5125620D (01.040:01)
Added Functions/Modified Specifications:
-
The following functions are invalidated when the system configures the
Plockmatic:
Shift tray full detection
Shift
tray
elevation
Shift tray jogger motion
-
If the Plockmatic does not acknowledge completion of a feed out for 27
seconds, jam in the Plockmatic is sent to the mainframe.
-
Since manual stapling is not supported by Plockmatic (BK5030)
specification has been modified to suspend printing by issuing "jam" status
during manual stapling operation.
Symptoms Corrected:
-
If the paper entrance sensor of the Columbia momentarily detects paper
during the initial sensor check, the Columbia sends to the mainframe a
"wait" signal one time but not a "jam" signal and remains in waiting status
The mainframe cannot detect the anomaly and attempts to print as soon
as completing the warm-up process, however, the Columbia is in a "wait"
status, and therefore, printing is suspended although the control panel
displays "printing".
Specification has been modified to issue a "jam" status and suspend
printing if the paper entrance sensor of the Columbia detects paper even i
momentarily during the initial check process.