2
An SSL error notification has been issued. Issued after the certification has expired.
3
Notification of shift from a common authentication to an individual certification.
4
Notification of a common certification without ID2.
5
Notification that no certification was issued.
6
Notification that GW URL does not exist.
69
CERT: Up ID
The ID of the request for certification.
83
Firmware Up Status
Displays the status of the firmware update.
84
Non-HDD Firm Up
This setting determines if the firmware can be updated, even without the HDD installed.
0: Not allowed update
1: Allowed update
85
Firm Up User Check
This SP setting determines if the operator can confirm the previous version of the firmware
before the firmware update execution. If the option to confirm the previous version is selected,
a notification is sent to the system manager and the firmware update is done with the firmware
files from the URL.
86
Firmware Size
Allows the service technician to confirm the size of the firmware data files during the firmware
update execution.
087
CERT: Macro
Displays the macro version of the @Remote certification.
88
CERT: PAC
Displays the PAC version of the @Remote certification.
89 CERT: ID2 Code
System Service Mode
169
8
Содержание BE-C1 D046
Страница 1: ...Model Be C1 Machine Code D046 D049 Field Service Manual August 2008 Subject to change...
Страница 2: ......
Страница 22: ...Configuration 3 Main Machine Folder FD6500B B890 2 Installation 20 2...
Страница 67: ...Paper Cassette Type 7140 D395 65 2...
Страница 81: ...6 Attach the size decals 7 Attach A Original stoppers B Original guides Tray and Stacker Options 79 2...
Страница 127: ...10 Open cover A 11 Attach the large mylars B to cover N5 Bridge Unit BU6500 D407 Folder FD6500A B889 125 2...
Страница 173: ...3 Remove the rear cover A of the cross fold unit x3 4 Remove cover A x1 Folder FD6500B Cross Folder B890 171 2...
Страница 180: ...23 Reattach cover A x1 24 Reattach cover A x3 2 Installation 178 2...
Страница 217: ...Installation 1 Remove the rear cover of the machine to expose the controller box A x8 MFP Options 215 2...
Страница 256: ...2 Installation 254 2...
Страница 257: ...3 Preventive Maintenance Preventive Maintenance The PM tables are included in the Appendices 255 3...
Страница 258: ...3 Preventive Maintenance 256 3...
Страница 268: ...3 Remove the controller box faceplate 1 x6 4 Remove the controller box cover 1 x11 4 Replacement and Adjustment 266 4...
Страница 286: ...8 Remove the left scanner plate 1 x2 9 Remove the right scanner plate 1 x2 4 Replacement and Adjustment 284 4...
Страница 287: ...10 Remove the CIS unit 1 Scanner Unit 285 4...
Страница 291: ...5 Remove the right exposure glass plate 1 x2 6 On the left pull out the exposure glass 1 Scanner Unit 289 4...
Страница 296: ...9 Remove the original junction gate 1 4 Replacement and Adjustment 294 4...
Страница 362: ...9 On the right remove the screws 1 and bearing 2 x2 10 Remove the hot roller 1 4 Replacement and Adjustment 360 4...
Страница 371: ...4 Remove screws 1 and 2 on the right and left x2 5 Remove the registration idle roller panel 1 Sensors Switches 369 4...
Страница 374: ...2 Disconnect the sensor assembly 1 x1 3 Remove the sensor 2 x1 Pawls x4 4 Replacement and Adjustment 372 4...
Страница 388: ...4 Use a wrench 1 to remove the BCU stand screws x3 5 Remove the IPU 2 4 Replacement and Adjustment 386 4...
Страница 446: ...6 Troubleshooting 444 6...
Страница 447: ...Model Be C1 Machine Code D046 D049 Appendixes August 2008 Subject to change...
Страница 448: ......
Страница 462: ...1 Appendix Specifications 14 1...
Страница 463: ...2 Appendix Overview Overview Machine Layout 1 Image Writing Unit 15 2...
Страница 484: ...Drum Drive Section 1 Drum Drive Gear Silicone Grease G501 4 Appendix Preventive Maintenance Tables 36 4...
Страница 528: ...7 Appendix Jam Detection 80 7...