SERVICE CALL CONDITIONS
B234/B235/B236/D101/D102/D103
4-68
SM
Spine Fold HP Sensor: Left (S60) Error
SC796-4
A
The spine fold plate did not reach the left
HP sensor (the sensor did not go ON) within
the prescribed time after the left spine fold
plate motor turned on.
-or-
The spine fold plate did not leave the left
HP sensor position (the sensor did not go
OFF within the prescribed time).
•
Spine fold plate motor: left
(M28) defective
•
Spine fold HP sensor: left
(S60) defective
•
Sensor connector loose,
broken, defective
Spine Fold Close Sensor: Left (S61) Error
SC796-5
A
The sensor did not turn ON within the
prescribed time, or the sensor was
already OFF when the spine fold plate
was supposed to move from the closed
to the open position.
-or-
The sensor did not go OFF within the
prescribed time after the spine fold plate
motor: left turned on to open the spine
fold plate, or the sensor was already ON
when the spine fold plate was supposed
to move from the open to the closed
position.
•
Spine fold plate motor: left
(M28) defective
•
Spine fold close sensor: left
(S61) defective
•
Sensor connector loose,
broken, defective
Dual Spine Plate Sensor Error: Left
SC796-6
A
The spine plate HP sensor (S60)
and spine plate close sensor (S63)
turned ON at the same time.
•
Spine fold HP sensor: left (S60)
defective
•
Spine fold close sensor (S63)
defective
•
A sensor connector loose, broken,
defective
Spine Fold HP Sensor: Right (S66) Error
The spine fold plate did not reach the right HP sensor within the prescribed
time (sensor did not go ON) after the spine fold plate motor (M29) turned on
to open the fold plate, or the right HP sensor was already OFF when the
spine fold plate was supposed to move from the open to the closed position.
-or-
The spine fold plate did not leave the right HP sensor position (sensor did not
go OFF) within the prescribed time after the spine fold motor: right turned on
to close the fold plate.
SC796-7
A
•
Spine fold motor: right (M29) defective
•
Spine fold HP sensor: right (S66) defective
•
Connector loose, broken, defective