Fan RPM calibration
After replacing the main board, blower, or updating the firmware, "Fan RPM Calibration" should be
done.
1.
While pressing the "Power" button, plug in the power cord.
2.
When the "Power LED" flashes red, release the "Power" button.
3.
After 3 to 5 seconds, the projector will power on.
4.
After the logo disappears, the message "Warning Factory Fan RPM Calculation now,
please wait...." will be shown on the screen.
5.
After 70 seconds, please get into Service Mode to check "Factory Blower RPM".
6.
The value of "Factory Blower RPM" should be from 2880 to 4320rpm.
If the "Factory Blower RPM" value does not appear in Service Mode, please repeat the step again.
3. Replacement and Adjustment
42
3
Содержание Antares-PJ1 Series
Страница 1: ...Model Antares PJ1 Machine Codes Y020 Y021 Y022 Field Service Manual 26 August 2011...
Страница 2: ......
Страница 10: ...8...
Страница 11: ...1 Product Information Specifications See Appendices for the following information General Specifications 9 1...
Страница 14: ...1 Product Information 12 1...
Страница 18: ...2 Installation 16 2...
Страница 57: ...6 Click Next 7 Click Next 8 Click Next The program is being installed Firmware Update 55 4...
Страница 61: ...6 Click Next 7 Click Finish Firmware Update procedure 1 Get into firmware update mode Firmware Update 59 4...
Страница 66: ...4 System Maintenance 64 4...
Страница 69: ...Main Procedures Main Procedures 67 5...
Страница 70: ...A No Power Troubleshooting 5 Troubleshooting 68 5...
Страница 72: ...If temp LED flashes 5 Troubleshooting 70 5...
Страница 73: ...If lamp LED lights Main Procedures 71 5...
Страница 74: ...If lamp LED flashes 5 Troubleshooting 72 5...
Страница 75: ...Only power LED light red Main Procedures 73 5...
Страница 76: ...C Image Troubleshooting 1 1 Does the PC image show on the screen 5 Troubleshooting 74 5...
Страница 77: ...1 2 Does video image show on the screen Main Procedures 75 5...
Страница 78: ...1 3 Does HDMI image show on the screen 5 Troubleshooting 76 5...
Страница 79: ...1 4 Is audio output normal Main Procedures 77 5...
Страница 80: ...1 5 Is focus ok 5 Troubleshooting 78 5...
Страница 81: ...1 6 Is color ok Main Procedures 79 5...
Страница 82: ...1 7 Have line bar 5 Troubleshooting 80 5...
Страница 83: ...1 8 Is there noise in the image Main Procedures 81 5...
Страница 84: ...1 9 Is uniformity ok 5 Troubleshooting 82 5...
Страница 85: ...D Remote Control Troubleshooting Main Procedures 83 5...
Страница 86: ...5 Troubleshooting 84 5...
Страница 87: ...Model Antares PJ1 Machine Codes Y0020 Y021 Y022 Appendices 24 October 2011...
Страница 88: ......
Страница 90: ...2...