Safety and Ecological Notes for Disposal
1. Never incinerate toner bottles or used toner. Toner dust may ignite suddenly when exposed to an
open flame.
2. Dispose of used toner, developer, and organic photoconductors in accordance with local
regulations. (These are non-toxic supplies.)
3. Dispose of replaced parts in accordance with local regulations.
4. When keeping used lithium batteries in order to dispose of them later, do not put more than 100
batteries per sealed box. Storing larger numbers or not sealing them apart may lead to chemical
reactions and heat build-up.
• The danger of explosion exists if a battery of this type is incorrectly replaced.
• Replace only with the same or an equivalent type recommended by the manufacturer. Discard
used batteries in accordance with the manufacturer's instructions.
Laser Safety
1. The Center for Devices and Radiological Health (CDRH) prohibits the repair of laser-based optical
units in the field.
2. The optical housing unit can only be repaired in a factory or at a location with the requisite
equipment.
3. The laser subsystem is replaceable in the field by a qualified Customer Engineer.
4. The laser chassis is not repairable in the field.
5. Customer engineers are therefore directed to return all chassis and laser subsystems to the factory
or service depot when replacement of the optical subsystem is required.
• Use of controls, or adjustment, or performance of procedures other than those specified in this
manual may result in hazardous radiation exposure.
• Turn off the main switch before attempting any of the procedures in the Laser Unit section. Laser
beams can seriously damage your eyes.
12
Содержание Aficio SP 100
Страница 1: ...Model ME P1 MF1_ww Machine Code M101 M102 M103 Field Service Manual 26 December 2011...
Страница 2: ......
Страница 75: ...5 Free the harness x1 6 At the front disconnect the fusing unit x4 Basic Procedures 73...
Страница 107: ...Solenoid 105...
Страница 122: ...Ground Plate 1 Note the correct position for the ground plate before re installation 4 Replacement and Adjustments 120...
Страница 124: ...3 Disconnect and remove the board x5 Re installation 4 Replacement and Adjustments 122...
Страница 128: ...8 Remove the center harness bracket 9 Remove the board Re installation 4 Replacement and Adjustments 126...
Страница 135: ...1 Disconnect the speaker harness x1 2 Disconnect and remove the speaker x1 x2 Boards 133...
Страница 139: ...7 Lay the rear cover on a flat surface 8 Disconnect the PSU x6 9 Remove the PSU Boards 137...
Страница 143: ...9 Press the tab release and remove the board x1 AIO Terminals Boards 141...
Страница 149: ...1 Separate both ends of the CIS from the cradles 2 Disconnect the CIS x1 Flatbed Scanner 147...
Страница 156: ...4 Replacement and Adjustments 154...
Страница 173: ...2 Enter the service mode to display the Service Mode screen 1 Fuser SC Detect Utilities 171...
Страница 227: ...Model ME P1 MF1_ww Machine Code M101 M102 M103 Appendices 08 March 2012...
Страница 228: ......
Страница 230: ...2...
Страница 244: ...Scan Area TWAIN Driver Flatbed Margin Width mm A Left 0 B Right 0 C Leading 0 D Trailing 0 1 Appendix Specifications 16...