Richmar APT Performer Скачать руководство пользователя страница 1

OPERATION MANUAL

APT Performer

Содержание APT Performer

Страница 1: ...OPERATION MANUAL APT Performer...

Страница 2: ...A PHYSICIAN LICENSED PRACTITIONER OR QUALIFIED MEDICAL PERSONNEL IN A CLINICAL ENVIRONMENT AND HAVE THE BASIC PHYSICAL COGNITIVE PREREQUISITES SUCH AS VISION HEARING AND LITERACY AS WELL AS BASIC FUNC...

Страница 3: ...ights and you may also have other rights which vary from location to location Richmar does not authorize any person or representative to create for it any other obligation or liability in connection w...

Страница 4: ...plains possible safety infractions that could have the potential to cause minor to moderate injury and or damage to equipment WARNING Text under a WARNING heading explains possible safety infractions...

Страница 5: ...ws of all adjustable parts of the device handlebar supporting module calf supports are tightened and intact Should they become loose during training stop the training immediately and tighten the screw...

Страница 6: ...erate the mains plug Ensure that the power cord is easily detachable in an emergency situation Take care not to allow water to enter the device Keep cables and electric components away from water and...

Страница 7: ...k fire or personal injury If a malfunction occurs discontinue use immediately disconnect the power cord from the outlet and contact tech support NEVER perform unauthorized service work All service wor...

Страница 8: ...1 Ligaments knees or joint ruptures 2 Post osteoporosis 3 Crippled limbs 4 A person with severe spasticity or stiffness in the limbs 5 Acute thrombosis 6 Pregnancy 7 Patients where vital signs are uns...

Страница 9: ...60 r min Resistance Level 0 24 Spasm Level 1 5 Spasm Relief Rate 1 5 Timer duration time 1 60 min 7 ELECTRICAL Power Supply AC100 240V 50 60Hz Rated Power 160 VA Mode of Operation Continuous System of...

Страница 10: ...ULT ROTATION FWD REV FWD SCREEN BRIGHTNESS 1 10 1 or 2 5 VOLUME 1 3 1 2 DEVICE DESCRIPTION TECHNICAL SPECIFICATIONS CONTINUED BLUETOOTH Bluetooth Version 4 0 Frequency Range 2 400 GHz 2 483 GHz Modula...

Страница 11: ...emove the device from packaging pulling upwards Remove the remaining foam material around all accessories INSPECTIONS Immediately upon unpacking the device perform the following steps 1 Verify the del...

Страница 12: ...nt is training from a wheelchair the wheelchair should be secured using the anti tipper wheelchair hooks with patients wheels in locked position to avoid any movement during training If the patient is...

Страница 13: ...of images below illustrating how to secure the patient s arms in the straps DEFINITIONS OF TRAINING PROGRAMS Strength Training Program Strength training is designed to encourage the patient to use mor...

Страница 14: ...t set correctly this could cause records to be lost or stored inaccurately Press the EDIT button to set the Date and Time then press OK button Set the value according to the local time before first us...

Страница 15: ...RPMs If CANCEL is pressed the previous interface will appear on the screen to lower the RPMs below 30 GAMEPLAY Each game interface shows tips about how to play each game Below is one example Game Sta...

Страница 16: ...ing please press the PAUSE button Adjust the parameters then press RESUME button to finish training Strength Training The Strength Training is designed to increase resistance when the big fish approac...

Страница 17: ...gram designed to encourage the patient to maintain an even balance between their left and right side The Symmetry training parameters and game are as shown below After the training parameters have bee...

Страница 18: ...the number of bugs that appear on the left and right of the screen Press the arrows to move the ratio to the right or left Read the game tips and tell the patient how to train then press OK button to...

Страница 19: ...Section for more details STORING AND RECALLING FAVORITES Storing Favorites To store a training session as a favorite to use for future trainings or on other patients press FAVORITES button from the T...

Страница 20: ...handlebar to break the motor circuit The trainer motor will stop immediately Prompt appears on the screen 2 Release emergency stop Reset the emergency stop button by pulling out the red button Then t...

Страница 21: ...ories must be checked at regular intervals INTERVAL ROUTINE MAINTENANCE WEEKLY OBVIOUS DAMAGE Visually inspect components for damage that could cause problems Check the power cord to ensure there is n...

Страница 22: ...ot adjustment knobs are not completely tightened 1 Place the trainer in a smooth position for training 2 Tighten the pivot adjustment knobs The heart rate displays 0 during training 1 The heart rate m...

Страница 23: ...n a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to ra...

Страница 24: ...th 0 5kV 1 kV line s to lines 0 5kV 1 kV 2 kV line s to earth Mains power quality should be that of a typical commercial or hospital environment Voltage dips short interruptions and voltage variations...

Страница 25: ...ronment guidance Conducted RF IEC 61000 4 6 3 Vrms 150 kHz 80 MHz 6 V rms in ISM bands between 150 kHz and 80 MHz 80 AM at 1 kHz 3 Vrms 150 kHz 80 MHz 6 V rms in ISM bands between 150 kHz and 80 MHz 8...

Страница 26: ...LTE Band 5 Pulse Modulation b 18 Hz 2 0 3 28 1720 1845 1970 1700 to 1990 GSM 1800 CDMA 1900 GSM 1900 DECT LTE Band 1 3 4 25 UMTS Pulse Modulation b 217 Hz 2 0 3 28 2450 2400 to 2570 Bluetooth WLAN 80...

Страница 27: ......

Страница 28: ......

Страница 29: ......

Страница 30: ...3428 20 09 C 2020 Compass Health Brands Corp Manufactured for Compass Health Brands Corp Toll Free 1 888 549 4945 6753 Engle Road Middleburg Heights OH 44130 richmarweb com...

Отзывы: