Junction Box Wiring
5
3.1
Connect Indicator
The indicator terminal strip is used to connect the main cable to the indicator.
1. Determine the indicator’s load cell input connections from the indicator manual.
2. Run a cable from the indicator terminal into the junction box through the cord grip.
Figure 3-2. Indicator Cable Location
3. Strip the wire insulation back 1/4'' to expose the wire.
4. Push in and hold the quick-connect lever with a small screwdriver.
5. Insert the appropriate wire into the exposed wire opening.
6. Release the screwdriver to allow the spring-loaded gate to close and lock the
wire in place.
If cables could be exposed to water or other liquids, bend a short downward loop in all
cables near the cord grips so any fluids draining down the cables will drip off before
reaching the junction box.
Figure 3-3. Drip Loop Cable
Indicator
Cable
Indicator
Cable
JB4EP and JB4SP
JB4ES and JB4SS