21. Lower deck onto scale frame.
IMPORTANT: Ensure load cells align with chrome ball in load cup in each corner.
Figure 4-9. Load Cell Alignment with Load Ball
22. Pull excess cable out of the junction box enclosure and tighten the cord grip dome nuts with a wrench.
NOTE: To be watertight, the nuts must be tightened to the point where the rubber sleeving begins to protrude out of the nut.
23. Pull each cable to ensure that they do not slip out of cord grip.
24. Reinstall junction box cover with six Phillips screws.
Figure 4-10. Reininstalling Junction Box Cover
25. Reinstall access cover with four hex screws.
IMPORTANT: Ensure access cover installs flush with deck.
Figure 4-11. Junction Box Access Cover Retaining Screws
Align Load Cup with
Chrome Ball
Reinstall Cover with
Six Phillips Screws
Reinstall Cover with
Four Hex Screws