Service Information
The following sections describe various troubleshooting and replacement parts information.
5.1 Troubleshooting
Problem
Probable Causes
Shift Error
Center of flexure is offset from the center line
Corners are not shimmed tightly to the floor
Nose-iron on power lever too high or too low
Pivot heads need shimming
Erratic Readings
Bent flexures or cable assembly
Center leveling bolts not down far enough, or down too low
Corners are not shimmed tightly to the floor
Ground shield not connected to cannon plug or meter shield
Loose connection in the junction box
Non-linear Weight Reading Center flexure is offset from the center line
Damage to the load cell
Misaligned flexure or cable assembly
Nose-iron on power lever too high or too low
Pivot heads need shimming
Corner Error
Corners are not shimmed tightly to the floor
Loose gripper
Misaligned flexure or cable assembly
Pivot heads need shimming
Zero Change
Corners not shimmed tightly to the floor
Damaged load cell
Live assembly touching the dead assembly
Loose gripper
Misaligned flexure or cable assembly
Shipping block has not been removed during unpacking
Obstruction under the load bridge (probably at the corner)
Table 5-1. Troubleshooting Table