1.2 Safety

Safety Signal Definitions:

Indicates an imminently hazardous situation that, if not avoided, will 

result in death or serious injury. Includes hazards that are exposed when 

guards are removed.
Indicates a potentially hazardous situation that, if not avoided could 

result in serious injury or death. Includes hazards that are exposed when 

guards are removed.
Indicates a potentially hazardous situation that, if not avoided, could 

result in minor or moderate injury.

Indicates information about procedures that, if not observed, could 

result in damage to equipment or corruption to and loss of data.

General Safety

Do not operate or work on this equipment unless this manual has been 

read and all instructions are understood. Contact any Rice Lake Weighing 

Systems dealer for replacement manuals. 

Failure to heed may result in serious injury or death.

Before attempting to operate this unit, make sure every individual who operates or works 

with this unit has read and understands the following safety information.

Do not allow minors (children) or inexperienced persons to operate this unit.

Do not operate without all shields and guards in place.

Do not jump up and down on the scale.

Do not use for purposes other then weight taking.

Do not place fingers into slots or possible pinch points.

Do not use any load bearing component that is worn beyond 5% of the original dimension.

Do not use this product if any of the components are cracked.

Do not exceed the rated load limit of the unit.

Do not make alterations or modifications to the unit.

Do not remove or obscure warning labels.

Keep hands, feet and loose clothing away from moving parts.

DANGER

WARNING

CAUTION

IMPORTANT

WARNING

Содержание RL9000 Series

Страница 1: ...RL9000 Series Weigh Module Kit Models TWM TWM HT Installation Manual PN 89284 Rev B July 1 2019...

Страница 2: ...marks of their respective companies All information contained within this publication is to the best of our knowledge complete and accurate at the time of publication Rice Lake Weighing Systems reserv...

Страница 3: ...234 9171 and asking for the training department 1 0 Introduction 1 1 1 Overview 1 1 1 1 Features 1 1 2 Safety Section 2 2 0 Load Cell Wiring 3 2 1 Junction Box Connections Adjustments and Calibration...

Страница 4: ...RL9000 Series Weigh Module Kit ii Visit our website www RiceLake com...

Страница 5: ...b load cells and transmit the load via a spherical washer on the load bearing hub of the cell The shear web design eases load cell installation and replacement without the need to raise the weighed ve...

Страница 6: ...ctions are understood Contact any Rice Lake Weighing Systems dealer for replacement manuals Failure to heed may result in serious injury or death Before attempting to operate this unit make sure every...

Страница 7: ...unction box Attach load cell cable to the dead structure Figure 2 1 Drip Loop 3 If conduit protection is needed against mechanical or rodent damage to the load cell cables use flexible conduit and con...

Страница 8: ...unction box If the problem is not found 1 Check possible indicator malfunction by using a load cell simulator to input a known good signal into the indicator 2 Disconnect each load cell s signal leads...

Страница 9: ...no more than 20 Add shims as needed to achieve correct load distribution Take extreme care to prevent overload damage A tank or hopper can exert huge forces when dropped only a fraction of an inch It...

Страница 10: ...embly Three areas which commonly cause accuracy problems to consider Are the supporting legs adequately braced so they will not spread when the system is fully loaded Does the supporting structure hav...

Страница 11: ...load distribution final height adjustments can be made with shims between the top plate loading bracket and the weighing vessel The variation in load among the cells should be no more than 20 The load...

Страница 12: ...city A B1 C D E F G H I Conduit Adapter 1K 10K 4 0 2 0 3 25 3 5 0 4 3 8 16 1 35 0 375 0 75 N A 15K 4 0 2 0 3 25 3 5 0 4 3 8 16 1 60 0 625 0 75 N A 20 50K 7 0 3 75 5 50 6 0 0 63 1 2 13 2 48 0 75 1 3 1...

Страница 13: ...Rights Reserved 9 5 2 150K to 200K Assembly Dimensions Inches Rated Capacity A B2 C D E F G H I Conduit Adapter 150K 200K 10 0 7 825 8 0 9 0 1 1 1 14 4 75 2 0 1 7 1 2 14 NPT Table 5 2 150 200K Assemb...

Страница 14: ...www RiceLake com 5 3 250K to 450K Assembly Dimensions Inches Rated Capacity A B2 C D E F G H I Conduit Adapter 250K 450K 11 0 7 75 9 0 9 0 1 3 7 8 14 6 42 3 0 2 25 1 2 14 NPT Table 5 3 250 450K Assemb...

Страница 15: ......

Страница 16: ...Canada Mexico 800 321 6703 International 715 234 9171 Europe 31 0 26 472 1319 Rice Lake Weighing Systems is an ISO 9001 registered company Rice Lake Weighing Systems Specifications subject to change w...

Отзывы: