Rice Lake RL1800 Series Скачать руководство пользователя страница 8

RL1800 Series Weigh Module Kit

4

Visit our website 

www.RiceLake.com

The load on each module should not more than 20%. During installation, add shims where 

needed to verify the correct load distribution is achieved on each module.

During installation, dummy load cells can be used to prevent overload damage. 

If the actual load cells are used during installation of the weigh module, 

extreme care must be taken to prevent overload damage. A tank or 

hopper weighing several tons can exert extreme forces when dropped 

only a fraction of an inch.

All piping or conduit must be horizontal and flexible sections close to the vessel. 

• If flexible piping is not used, make sure the distance from the vessel to the first 

pipe support is 20-30 times the pipe diameter. 

• In smaller, lower capacity tanks and hoppers, isolating the resultant forces 

becomes extremely critical. 

• If possible, use flexible conduit piping close to the vessel instead of the rigid 

variety. 

• See the Weigh Modules & Vessel Weighing Systems manual (PN 22054) for more 

information.

Figure 2-3. Piping and Conduit

  Load cells should not be installed in modules until welding is completed. 

The heat generated from welding current passing through a load cell can damage the 

adhesive holding the strain gauge to the body. 

• If possible, use a dummy load cell when welding to maintain finished height. 

• If welding is unavoidable after load cell installation, ground in such a manner as to 

prevent welding current from passing through the load cell. 

• Ground the welder as closely as possible to the point of welding. 

  Never rely on check rods or piping for grounding.

When possible, use hermetically sealed load cells in washdown applications.

• Environmentally protected load cells are not suitable for such applications and will 

be damaged. 

IMPORTANT

Flexible Piping

Junction Box

Level ± 0.5°

IMPORTANT

IMPORTANT

Содержание RL1800 Series

Страница 1: ...RL1800 Series Weigh Module Kit Installation Manual PN 25712 Rev B December 5 2018...

Страница 2: ...marks of their respective companies All information contained within this publication is to the best of our knowledge complete and accurate at the time of publication Rice Lake Weighing Systems reserv...

Страница 3: ...can be viewed at www ricelake com training or obtained by calling 715 234 9171 and asking for the training department 1 0 Introduction 1 1 1 Overview 1 1 2 Safety 2 2 0 Mechanical Installation 3 2 1...

Страница 4: ...Series Weigh Module Kit ii Visit our website www RiceLake com Rice Lake continually offers web based video training on a growing selection of product related topics at no cost Visit www ricelake com w...

Страница 5: ...website at www ricelake com manuals Warranty information can be found at www ricelake com warranties 1 1 Overview The module is available in two sizes Small accepts load cells with capacities from 25...

Страница 6: ...ruption to and loss of data General Safety Do not operate or work on this equipment unless this manual has been read and all instructions are understood Contact any Rice Lake Weighing Systems dealer f...

Страница 7: ...long dimension of the vessel Figure 2 2 Rectangular Mounting In any application where a recurring force is present in one direction such as in a conveyor belt or roller platform the long axis of the...

Страница 8: ...t forces becomes extremely critical If possible use flexible conduit piping close to the vessel instead of the rigid variety See the Weigh Modules Vessel Weighing Systems manual PN 22054 for more info...

Страница 9: ...g and assembling the RL1800 Weigh Module Carefully consider three areas which commonly cause accuracy problems Are the supporting legs adequately braced so they will not spread when the system is full...

Страница 10: ...gnment between the base plate and top plate by lifting the vessel slightly at each support point in turn This also indicates if the load is evenly distributed on all modules 11 Shim as needed this onl...

Страница 11: ...he cables onto the load cells or the junction box 3 Attach load cell cable to the dead structure not the vessel 4 If conduit protection is necessary against mechanical or rodent damage to the load cel...

Страница 12: ...especially in the junction box If the problem is not found 1 Check possible indicator malfunction by using a load cell simulator to input a known good signal into the indicator 2 Disconnect each load...