Mechanical to Electronic Installation Instructions
©
Rice Lake Weighing Systems
●
All Rights Reserved
19
12. If using a 6-wire load cell cable (with sense wires), remove jumpers JP3 and JP4 on the A/D board before reinstalling
). For 4-wire installation, leave jumpers JP3 and JP4 on.
Figure 4-8. 482 Legend Series Indicator Board
4.3 Final Adjustment, Calibration and Troubleshooting
Final adjustment, calibration and troubleshooting of the 482 indicator can be found in the 482 Technical Manual, PN 165124.
20mA_Out
RXD1
T
XD1
GND
RXD2
T
XD2
GND
GND
Sig+
SIG-
SEN+
SEN-
EX
C+
EX
C-
Load Cell Connection
RS-232
Connection
20mA
Connection
CPU Board PN 131318
A/D Board PN 131319
J1
J2
J13
J17
J5
J6
J15
J16
J14
J7 to display board
J2
J10
J3 J4
Sense Jumpers
J9