Configuration
© Rice Lake Weighing Systems
●
All Rights Reserved
43
Password
Configurable passwords to secure the User and Setup menus; ensure the audit jumper (J24) is in the ON position when using
the Setup password; 999999 can be entered to overwrite either password if forgotten, overwriting the password clears
configuration and calibration settings (use Revolution to backup settings before overwriting);
Sub-Parameters:
User – User menu password secures the user menu with configured password;
Enter characters: Up to 16 alphanumeric characters
Setup – Setup menu password secures the setup menu with configured password;
Enter characters: Up to 16 alphanumeric characters
Consecutive Number Allows sequential numbering for print operations; the value is incremented following each print operation which includes
<CN> in the ticket format;
Enter value:
0–9999999,
0
(default)
Consecutive Number
Start
Specifies the initial consecutive number value used when the consecutive number is reset by sending Clear Consecutive
Number digital input;
Enter value:
0–9999999,
0
(default)
Unit ID
Specifies the unit identification with an alphanumeric value;
Enter characters: Up to 6 alphanumeric characters,
1
(default)
Contact
Contact Information; See
Accumulator
Accumulation can be toggled On/Off; if On, accumulation occurs on print operation; if Off, an accumulation does not occur;
Settings:
Off
(default), On
Weighment Threshold When the weight falls below the value set, the accumulator is rearmed;
Enter value: 0.0–9999999.0,
1000.0
(default)
Number of
Weighments
Displays the total number of weighments (read only)
Maximum Weight
Displays the maximum weight/weighment allowed (read only)
Date of Maximum
Weight
Displays the date and time the maximum weight/weighment occurred (read only)
Date
Allows setting of the date format and date separator character
Date Format –
Settings:
MMDDYY
(default), DDMMYY, YYMMDD, YYDDMM
Date Separator –
Settings:
Slash
(default), Dash, Semi, Dot
Time
Allows setting of the time format and the separator character
Time Format –
Settings:
12HOUR
(default), 24HOUR
Time Separator –
Settings:
Colon
(default), Comma, Dot
Keyboard Lock
Disables the keyboard except for the menu and power key;
Settings:
Off
(default), On
Lock All Keys
Except Zero
Disables the keyboard except for the zero, menu and power keys;
Settings:
Off
(default), On
Key Hold
Allows setting of the key hold time and interval
Key Hold Time – How long a key needs to be held before a key hold action is initiated (in tenths of a second);
20 equals 2 seconds;
Enter value: 10–50,
20
(default)
Key Hold Interval – The amount of time between increments during a key hold (in twentieths of a second);
2 equals a tenth of a second (10 increments per second during a key hold);
Enter value: 1–100,
2
(default)
Locale
Enables location gravity compensation;
Settings:
Off
(default)
– gravity compensation disabled
On
– calculates gravity compensation using the origin and destination latitudes and elevations
Factor
– uses origin and destination gravity factors to find gravity compensation
Origin Latitude
Origin latitude (to nearest degree) for gravity compensation; displays when Locale parameter is set to On;
Enter value: 0–90,
45
(default)
Origin Elevation
Origin elevation (in meters) for gravity compensation; displays when Locale parameter is set to On;
Enter value: -9999–9999,
345
(default)
Destination Latitude
Destination latitude (to nearest degree) for gravity compensation; displays when Locale parameter is set to On;
Enter value: 0–90,
45
(default)
Destination Elevation Destination elevation (in meters) for gravity compensation; displays when Locale parameter is set to On;
Enter value: -9999–9999,
345
(default)
Origin Gravity
Origin gravity factor (in m/s
2
) for gravity compensation; displays when Locale parameter is set to Factor;
Enter value: 9.00000–9.99999,
9.80665
(default)
Destination Gravity
Destination gravity factor (in m/s
2
) for gravity compensation; displays when Locale parameter is set to Factor
;
Enter value: 9.00000–9.99999,
9.80665
(default)
Persistent Tare
Tare persists through a power cycle;
Settings:
Off
(default), On
Remote Print
Destination
Specifies if the 682 (Local) or another indicator (Remote) handles the print key;
Settings:
Remote
(default), Local
Table 4-15. Program Menu Parameters (Continued)