EDP Commands
© Rice Lake Weighing Systems
●
All Rights Reserved
49
7.8 Feature Commands
7.9 Regulatory Commands
Command
Description
Values
DATEFMT
Date format
MMDDYY
(default), DDMMYY, YYMMDD, YYDDMM
DATESEP
Date separator
SLASH
(default), DASH, SEMI, DOT
TIMEFMT
Time format
12HOUR
(default), 24HOUR
TIMESEP
Time separator
COLON
(default), COMMA, DOT
CONSNUM
Consecutive numbering
0–9999999,
0
(default)
CONSTUP
Consecutive number start-up value
0–9999999,
0
(default)
UID
ID of the indicator
Up to 6 alphanumeric characters,
1
(default)
KYBDLK
Keyboard lock (disable keypad)
OFF
(default), ON
ZERONLY
Disable all keys except ZERO
OFF
(default), ON
CONTACT.COMPANY
Contact company name
Up to 30 alphanumeric characters
CONTACT.ADDR1-3
Contact company address
Up to 30 alphanumeric characters (for each line)
CONTACT.NAME1-3
Contact names
Up to 30 alphanumeric characters (for each line)
CONTACT.PHONE1-3
Contact phone numbers
Up to 30 alphanumeric characters (for each line)
CONTACT.EMAIL
Contact e-mail address
Up to 30 alphanumeric characters.
CONTACT.NEXTCAL
Next calibration date
Date MMDDYYYY as an 8-digit number.
CONTACT.LASTCAL
Last calibration date
Date MMDDYYYY as an 8-digit number.
LOCALE
Enable gravity compensation
OFF
(default), ON
LAT.LOC
Origin latitude (to nearest degree) for gravity compensation
0–90,
45
(default)
ELEV.LOC
Origin elevation (in meters) for gravity compensation
-9999–9999,
345
(default)
DEST.LAT.LOC
Destination latitude (in degrees) for gravity compensation
0–90,
45
(default)
DEST.ELEV.LOC
Destination elevation (in meters) for gravity compensation
-9999–9999,
345
(default)
Table 7-8. Feature Commands
Command
Description
Values
REGULAT
Regulatory mode
NTEP
(default), CANADA, INDUST, NONE, OIML
AUDAGNCY
Audit Agency (Industrial Mode)
NTEP
(default), CANADA, NONE, OIML
REG.SNPSHOT
Display or Scale weight source
DISPLAY
(default), SCALE
REG.HTARE
Allow tare in display hold
NO
(default), YES
REG.ZTARE
Remove tare on ZERO
NO
(default), YES
REG.KTARE
Always allow keyed tare
NO,
YES
(default)
REG.MTARE
Multiple tare action
REPLACE
(default), REMOVE, NOTHING
REG.NTARE
Allow negative tare
NO
(default), YES
REG.CTARE
Allow Clear key to clear tare/accumulator
NO,
YES
(default)
REG.NEGTOTAL
Allow total scale to display negative value
NO
(default), YES
REG.PRTMOT
Allow print while in motion
NO
(default), YES
REG.PRINTPT
Add PT to keyed tare print
NO,
YES
(default)
REG.PRTHLD
Print during display hold
NO
(default), YES
REG.HLDWGH
Allow weighment during display hold
NO
(default), YES
REG.MOTWGH
Allow weighment in motion
NO
(default), YES
REG.OVRBASE
Zero base for overload calculation
CALIB
(default), SCALE
REGWORD
Regulatory word
GROSS
(default), BRUTTO
REG.RTARE
Round the Pushbutton Tare
NO
(default), YES
REG.RKTARE
Round the Keyed Tare
NO
(default), YES
REG.AZTNET
Perform AZT on Net value
NO
(default), YES
REG.MANUALCLEARTARE
Allows manual clearing of the tare value
NO,
YES
(default)
REG.TAREINMOTION
Allows Tare in Motion
NO
(default), YES
REG.ZEROINMOTION
Allows scale to be zeroed while in motion
NO
(default), YES
REG.UNDERLOAD
Underload weight value in display divisions
1–9999999,
20
(default)
Table 7-9. Regulatory Commands