Load Cell #1
Load Cell #2
Load Cell #4
Load Cell #3
Scale Cable
Junction Box
Trimmers
Load Cell #4
Load Cell #1Load Cell #2
Load Cell #3
Indicator
Black
Green
White
Shield
Red
+E
-E
+S
-S
GND
V1
V2
V3
V4
Load cell wiring shown is effective for all models later
then 09/17/2013, models built prior that date should
rewire the scale to the updated configuration. For
information on rewire, download Technical Bulletin
(PN 159193) from www.ricelake.com
Note
17
MAS-P Animal Scale Operator’s Manual
Figure 5-2. Load Cell Wiring Diagram
D
A
B
Indicator
A
D
C
B
Scale
A -EXC Black
B +SIG Green
C +EXC Red
D -SIG White
Connector
C
Figure 5-3. Scale/Indicator System Connection