Rice Lake Ishida IPC-WP 15 Скачать руководство пользователя страница 6

 3/32 

IPC-WP Series Service Manual

 

 

Chapter 1.  Product Overview 

1.1 Product 

Overview 

  The IPC-WP Series is a water proof type digital scale which can be operated with two batteries. 

  The large LCD with 25mm height is provided for the display. 

 
 

1.2 Standard 

Specifications 

Item 

Description 

Model name 

IPC-WP Series /IPC-WP DUAL Series 

IPC-WP 3 

IPC-WP 6 

IPC-WP 15 

Non-OIML(ASIA)

 

Weighing capacity 

3kg 6kg 15kg 

Single range 

Single range 

Single range 

Scale unit 

0.001kg 0.002kg 0.005kg 

3.000kg/0.001kg 6.000kg/0.002kg 15.000kg/0.005kg 

Accuracy 1/3000 

OIML R76 Class lll

 

Weighing capacity 

3kg 6kg 15kg 

Multi interval  

Multi interval 

Multi interval 

Scale unit 

0kg to 1.5kg/0.001kg 
1.5kg to 3kg/0.002kg 

0kg to 3kg/0.002kg 
3kg to 6kg/0.005kg 

0kg to 7.5kg/0.005kg 
7.5kg to 15kg/0.01kg 

Accuracy 1/1500 

1/1200 

1/1500 

lb/kg Switching Specification (USA)

 

Weighing capacity 

6lb/3kg 15lb/6kg 30lb/15kg 

Multi interval  

Multi interval 

Multi interval 

Scale unit 

0lb to 3lb/0.002lb 

 3lb to 6lb/0.005lb 

0lb to 7.5lb/0.005lb 

 7.5lb to 15lb/0.01lb 

0lb to 715lb/0.01lb 

 15lb to 30lb/0.02lb 

(0kg to 1.5kg/0.001kg) 

(1.5kg to 3kg/0.002kg)

(0kg to 3kg/0.002kg) 
(3kg to 6kg/0.005kg) 

(0kg to 7.5kg/0.005kg) 
(7.5kg to 15kg/0.01kg) 

Accuracy 1/1500 
Weigh platter size 

196mm(L)×226mm(W) 

Display 

Single display / Dual diaplay 
LCD type 6 digits (7segments)  Height : 25mm

 

Environment condition 

Ambient temperature: -5

º

C to +40

º

Relative humidity: 80%RH (Max.), no condensation 

Power source 

Two D-sized dry batteries or AC adaptor  
[ Battery duration ] 
Two alkaline D-sized batteries (Approximately 500 hours) 

Current consumption 

Max. 25mA 

Auto power off 

Select: 60 minutes (default), 20 minutes or non Auto power off 

Weight (excl. battery) 

3.2kg 

Содержание Ishida IPC-WP 15

Страница 1: ......

Страница 2: ......

Страница 3: ...of life or serious injury Caution Indicates information that if not avoided could result in relatively serious or minor injury damage to the machine or faulty operation 2 Explanatory symbols Symbol M...

Страница 4: ...ustment 14 2 7 1 Operation 14 2 8 F Mode Setting Measuring Conditions and E2ROM Clear 15 2 8 1 Operation 15 2 8 2 Error No List 16 Chapter 3 Hardware Configuration 17 3 1 Mechanisms 17 3 1 1 Dual Disp...

Страница 5: ......

Страница 6: ...g to 7 5kg 0 005kg 7 5kg to 15kg 0 01kg Accuracy 1 1500 1 1200 1 1500 lb kg Switching Specification USA Weighing capacity 6lb 3kg 15lb 6kg 30lb 15kg Multi interval Multi interval Multi interval Scale...

Страница 7: ...Output voltage must not exceed 6 0V even if power supply voltage is at 10 2 Output voltage exceeds 3 2V even if power supply voltage is at 15 y Generally AC adaptor output voltage varies with load cur...

Страница 8: ...5 32 IPC WP Series Service Manual 1 3 Appearance Front Rear view Bottom view Memory switch Battery cover assy Two D sized dry batteries Battery rubber plug option Sheet 3...

Страница 9: ...6 32 IPC WP Series Service Manual 1 4 Operation Panel ASIA Specification Oceania Specification...

Страница 10: ...7 32 IPC WP Series Service Manual EU Specification USA Specification...

Страница 11: ...8 32 IPC WP Series Service Manual 1 5 Outer Dimensions Unit mm...

Страница 12: ...ow Note Press the memory switch at any time during test mode to record the data to the E2PROM Then P EP appears in the display Program No display START L003b TARE TARE Setup of scale No and decimal po...

Страница 13: ...a selection x Increments values for each press during data change x Press when entering C3 or F mode Memory Switch Tactile switch in the main circuit board Stores E2ROM data set for each item of the C...

Страница 14: ...0 0 1 0 0 Cleaning tare weight by pressing ZERO key 0 No 1 Yes 8 D3 0 0 1 0 0 0 1 Decimal point Indicator 0 1 1 101 D4 0 0 0 1 0 0 0 Over scale indication 0 BLANK 1 OL 2 D5 0 0 0 0 1 0 0 Tare subtract...

Страница 15: ...interval 30000 25 10 3 15kg 10g 5g Multi interval 30000 20 10 4 30kg 20g 10g Multi interval 30000 20 10 5 3kg 1g Single range 30000 10 6 6kg 2g Single range 30000 10 7 15kg 5g Single range 30000 10 8...

Страница 16: ...IA 3kg 1g Single range X1 5 X2 4 2 1 Scale No Setting x Press the key ON four times X1 5 X2 X1 X2 X1 2 2 Decimal point indication Setting x Press the ZERO key ON 2nd digit flashes X2 X1 x Press the ke...

Страница 17: ...5000 counts 2 5 Put the weight same as weighing capacity on the weigh platter then press the key CAL is displayed then the A D count becomes 35000 on the display If the count diverges from 5000 count...

Страница 18: ...lected 2 3 Whenever the key is pressed the figure of the digit which has blinked does the increment 3 E2ROM clear Any scene of F mode is possible Press the ZERO key and key EP C then C1 1 is displayed...

Страница 19: ...4 Measurement condition 2 8 2 Error No List Error No Mode Item Err1 At power ON E2PROM unsetting or garbled data Err2 At power ON Outside start range Err3 Test mode Outside range where zero point can...

Страница 20: ...17 32 IPC WP Series Service Manual Chapter 3 Hardware Configuration 3 1 Mechanisms 3 1 1 Dual Display...

Страница 21: ...SE 1 17 LEVEL UNIT 1 18 O RING RUBBER 3 75 1 8 10 19 Varied per country 20 SLEEVE 2 21 SHEET_3 5 22 SPONGE BATTER COVER 1 23 BATTERY COVER ASSY 1 24 Varied per country 25 SHEET_2 1 26 FOOT LEVEL 4 27...

Страница 22: ...19 32 IPC WP Series Service Manual 3 1 2 Single Display...

Страница 23: ...SADDLE 1 16 BASE 1 17 LEVEL UNIT 1 18 O RING RUBBER 3 75 1 8 10 19 Varied per country 1 20 SLEEVE 2 21 SHEET_3 5 22 SPONGE BATTER COVER 1 23 BATTERY COVER ASSY 1 24 Varied per country 3 25 SHEET_2 1...

Страница 24: ...Electric Concerns 3 2 1 Block Diagram LOAD CELL FERRITE CORE PWB PS 021A MAIN PWB PS 022 KEY PWB PS 019 PWB PS 023 DISPLAY DUAL DISPLAY AC adapter Dealer Option D size dry batteries FERRITE CORE 3 ty...

Страница 25: ...1 JP4 JP5 JP6 Note There is no grounding wire in the maintenance parts LCD side G ND W R Connector CN1 Key input Pin No Function Remarks 1 GND 2 SW4 tare 3 SW3 4 SW2 zero 5 SW1 ON OFF CN2 Power source...

Страница 26: ...put Pin No Soldering land Function Remarks 1 R Vcc DC5V 2 W GND GND 3 G IN Approx 2 5V 4 B IN Approx 2 5V 5 GND GND GND Jumper JP1 Ferrite cut JP2 Ferrite cut JP3 Ferrite cut JP4 Ferrite cut JP5 Filte...

Страница 27: ...oard PS 022 y Harness Pin No Function Remarks BR GND R SW4 tare O SW3 Y SW2 zero G SW1 ON OFF 3 2 4 Dual Display Board PS 023 PS LCD 3 2 5 Connection Board PS 019 NC1 NC3 NC2 PS 019 2 1 2 4 3 CN2 CN1...

Страница 28: ...embly Procedure 1 When using dry batteries remove them before disassembly or assembly When using an AC adaptor disconnect it before disassembly or assembly 2 Remove the weighing platter 3 Remove the W...

Страница 29: ...nt first the water proofing property will be deteriorated because you cannot push in the packing between the upper case and the base evenly 8 Pull out the connector from CN1 on the main board then rem...

Страница 30: ...Remove the grounding wire by using a soldering iron 6 Perform the procedure in reverse when assembling a new main board 7 After re assembling all the parts from the case to the weighing platter clear...

Страница 31: ...rocedure in reverse for re assembly 4 1 5 Load Cell Replacement 1 Disconnect the cell cord wires and the grounding wires by using a soldering iron in the same manner as for Switch Board Replacement PS...

Страница 32: ...move the 4 Screws M5x5 The picture shows the position of the screws M5x5 The two screws on the right side include a collar flat washer and spring washer The other two screws on the left side include a...

Страница 33: ...e clearance limit by tightening the screw spring washer and flat washer on the plate support 2 When you finish adjusting the clearance paste the screw lock coagulant The clearance limit is shown below...

Страница 34: ...d SUS ring outside 3 Perform the procedure in reverse for assembly Caution When re assembling the scale fasten screws tentatively then tighten them completely one by one in a diagonal sequence If you...

Страница 35: ...ight value is unstable Check if something comes in contact with the platter If so remove it Check if there is wind or vibration near the machine If so avoid these Replace the main board PS 021 Replace...

Страница 36: ......

Страница 37: ......

Страница 38: ...PN 86367 01 2012...