![Rice Lake Ishida IPC-WP 15 Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/rice-lake/ishida-ipc-wp-15/ishida-ipc-wp-15_service-manual_1454167035.webp)
32/32
IPC-WP Series Service Manual
4.2 Troubleshooting
Symptom
Cause
Measure
1. The display check does not
start when the power switch
is pushed.
1. Trouble of dry battery
power supply system
•
Check and replace dry batteries
•
Confirmation and exchange of battery
harness
2. AC adaptor trouble
•
Check output voltage (DC2.4-6.0V)
and replace AC adaptor
3. Main board PS-021
trouble
•
Replace the main borad PS-021.
2. Power ON
→
Display check
→
"Err1"
1. Garbled E2ROM data or
initialized state.
•
Initialize, perform C1, and C2 and C3
settings, then push the memory
switch.
2. Main board PS-021
trouble
•
Replace the main board PS-021.
3. Power ON
→
Display check
→
"Err2"
1. Outside weight value start
range
•
Check if anything is placed on the
platter. If so, remove it.
•
Replace the load cell.
•
Replace the main board PS-021.
4. Power ON
→
Display check
→
“0”kg does not appear on
the display.
1. Weight value is unstable.
•
Check if something comes in contact
with the platter. If so, remove it.
•
Check if there is wind or vibration near
the machine. If so, avoid these.
•
Replace the main board PS-021.
•
Replace the load cell.
5. Weight varies at four
corners.
1. External or load cell
trouble
•
Check if the horizontal state is being
kept.
•
Check if there is foreign article
between the platter and the case.
•
Check if space of limit adjustment
screw is narrow
•
Replace the load cell.
6. The ZERO or TARE key
does not function.
1. Outside of
zero-adjustment or tare
subtraction range
•
Check that zero-adjustment or tare
subtraction is within the specified
range.
2. Weight value is unstable.
•
Check if something comes in contact
with the platter. If so, remove it.
•
Check if there is wind or vibration near
the machine. If so, avoid these.
•
Replace the main board PS-021.
•
Replace the load cell.
7. The power supply cuts
when time passes.
1. Auto power OFF setting.
•
Check if the auto power OFF function
works.
•
Default is 60 minutes.
2. Main board PS-0 21
trouble
•
Replace the main board PS-021.
Содержание Ishida IPC-WP 15
Страница 1: ......
Страница 2: ......
Страница 5: ......
Страница 9: ...6 32 IPC WP Series Service Manual 1 4 Operation Panel ASIA Specification Oceania Specification...
Страница 10: ...7 32 IPC WP Series Service Manual EU Specification USA Specification...
Страница 11: ...8 32 IPC WP Series Service Manual 1 5 Outer Dimensions Unit mm...
Страница 20: ...17 32 IPC WP Series Service Manual Chapter 3 Hardware Configuration 3 1 Mechanisms 3 1 1 Dual Display...
Страница 22: ...19 32 IPC WP Series Service Manual 3 1 2 Single Display...
Страница 36: ......
Страница 37: ......
Страница 38: ...PN 86367 01 2012...