background image

 

Introduction

 

1

 

About This Manual

 

This manual is intended for use by service technicians
responsible for installing and servicing the ethernet
option in Ishida 3000 Series scales and printers.

 

Authorized distributors and their employees
can view or download this manual from the

 

Rice Lake Weighing Systems

 

 distributor site at

 

www.ishidaretail.com

 

 

1.0

Introduction

 

If the ethernet option is ordered at the time the scale is
ordered, the ethernet card will be factory installed by
Rice Lake Weighing Systems. If a scale is received
with the ethernet option already installed, please
proceed directly to Section 2.0 on page 3 to begin
configuring the scale’s IP address, gateway IP address,
netmask, and Telnet configuration password.

 

1.1

Installation and Wiring

 

The following steps explain the installation and wiring
procedures for the ethernet option of the Ishida 3000
Series scales and printers.

 

1.1.1

Connector Mounting Bracket Removal

 

1. Remove platter.

2. Remove the display pole from the scale.

3. Remove keyboard assembly by removing two

screws and one 8mm hex screw. Gently lift
keyboard off and detach cable from main cpu
board. Set aside. (see Figure 1-1).

 

Figure 1-1. Remove Keyboard Assembly

 

4. Remove 4-7mm hex screws holding spider

assembly.

5. Remove 4-7mm hex screws beneath corners

of spider.

6. Remove 8mm hex screw next to nylon screw

near front of unit. 

7. Lift cover off scale.

8. Remove connector mounting by removing the

three screws holding the bracket and one
holding the power cord ground:

Both DB9 connectors (standoff 5mm).

Black cover (2 screws - phillips screwdriver).

Power switch (see Figure 1-2).

 

Figure 1-2. Power Switch Wiring

 

Fuse holder (see Figure 1-3).

Remove phillips screw next to the fuse holder.

Tighten nylon tie around metal locking tabs.

 

Figure 1-3. Fuse Holder

 

Power cord. Remove the black and white
w i r e s   f r o m   c o n n e c t o r   h o u s i n g   ( S e e
Section Figure 1-4. on page 2).

Power cord connection. Lightly pull wire and
pin out of connector to remove the black and
white wires from the connector slide plastic
tube over pin.

Rear view of
power switch

Содержание Ishida 3000 Series

Страница 1: ...69867 Ishida3000Series Scales and Printers Ethernet Configuration Manual...

Страница 2: ...3 2 2 Basic Parameters 3 2 3 Exit Configuration Mode 3 2 4 Parameters 4 2 4 1 Entering Telnet Session 4 2 4 2 Setting the Scale s IP Address 4 2 4 3 Setting the Scale s TCP IP Connection 4 2 4 4 Setti...

Страница 3: ...cket Removal 1 Remove platter 2 Remove the display pole from the scale 3 Remove keyboard assembly by removing two screws and one 8mm hex screw Gently lift keyboard off and detach cable from main cpu b...

Страница 4: ...ap onto mouting bracket 6 Place sticker over the DB 25 hole 7 Snap power cord pins back into connector Refer to Figure 1 4 for correct orientation 8 Assemble ethernet board and DB 25 board as pictured...

Страница 5: ...t 9999 and set all required parameters Telnet 128 1 1 215 1 3 Open a Telnet connection to port 9999 and set all required parameters Telnet 128 1 1 215 9999 NOTE The temporary IP address by ARP clears...

Страница 6: ...etting unchanged press ENTER To change a setting enter the new value and press ENTER In the example above only the last value of the IP address was changed After entering the last value the current se...

Страница 7: ...e 38400 I F Mode 78 Flow 00 Port 03001 Datagram Type 01 Pack Cntrl 10 SendChars 06 04 Remote IP Adr none Port 00000 2 4 5 Ending the Telnet Session To end the Telnet session select Save and exit by en...

Страница 8: ...3 14820 4 40 x 1 4 nylon screen 3 55878 4 40 Hex nut nylon 1 68435 Standoff 3 16 Hex male female 1 4 long 4 40 thread RAF 440 n 0 2 68434 Standoff 3 16 Hex male female 3 8 long RAF 2 68436 Washer nyl...

Страница 9: ...3 255 255 xxx These networks are the most common and are often used in small companies These networks can consist of a maximum number of 254 hosts Example 192 7 1 9 network 192 7 1 host 9 The remainin...

Страница 10: ...ant to operate your scale on an Intranet you should use one of the sub networks listed below These network numbers have been reserved for such numbers If you have any questions about IP assignment con...

Страница 11: ...ally exists and was not caused by accident misuse neglect alteration improper installation improper repair or improper testing RLWS shall be the sole judge of all alleged non conformities Such equipme...

Отзывы: