68
920i
Installation Manual
9.1.2
Reporting Commands
Reporting commands (see Table 9-2) send speciÞc
information to the serial port. These commands can be
used in both setup mode and normal mode.
9.1.3
The RESETCONFIGURATION Command
The RESETCONFIGURATION command can be
used in setup mode to restore all conÞguration
parameters to their default values.
The RESETCONFIGURATION function can also be
initiated by pressing the
Reset Config
softkey under
the VERSION menu.
NOTE:
All load cell calibration settings are lost when the
RESETCONFIGURATION command is run.
9.1.4
Parameter Setting Commands
Parameter setting commands allow you to display or
change the current value for a particular conÞguration
parameter (Tables 9-3 through 9-10).
Current conÞguration parameter settings can be
displayed in either setup mode or normal mode using
the following syntax:
command
<ENTER>
Most parameter values can be changed in setup mode
only; setpoint parameters listed in Table 9-6 on
page 71 can be changed when in normal weighing
mode.
Use the following command syntax when changing
parameter values:
command
=
value
<ENTER>
where
value
is either a number or a parameter value.
Use no spaces before or after the equal (=) sign. If you
type an incorrect command, the display reads
??
.
For example, to set the motion band parameter on
Scale #1 to 5 divisions, type the following:
SC.MOTBAND#1
=
5D
<ENTER>
For parameters with selectable values, enter the
command and equal sign followed by a question
mark:
command
=
?
<ENTER>
to see a list of those values. The indicator must be in
setup mode to use this function.
NOTE:
Some parameters are valid only if other
parameters or parameter values are specified. See the
configuration menus in Section
information about parameter dependencies. Restrictions
for front-panel configuration also apply to serial command
configuration.
Command
Function
DUMPALL
List all parameter values
SPDUMP
Print setpoint configuration
VERSION
Write
920i
software version
S#
n
Write one frame of stream format to scale
channel
n
HARDWARE
Lists option cards installed in slots 1–14. See
Section
information about using the HARDWARE
command.
PCLR
Program clear: erases the loaded user
program.
Table 9-2. Serial Reporting Commands
RS
Reset system: resets indicator without
resetting the configuration.
XE
Returns a10-digit code representing any error
conditions currently shown on the front panel.
See Section
information.
Command
Function
Table 9-2. Serial Reporting Commands (Continued)
Command
Description
Values
SC.GRADS#
n
Graduations
1–9999999
SC.ZTRKBND#
n
Zero track band
OFF, 0.5D, 1D, 3D
SC.ZRANGE#
n
Zero range
1.9%, 100%
SC.MOTBAND#
n
Motion band
1D, 2D, 3D, 5D, 10D, 20D, OFF
SC.SSTIME#
n
Standstill time
1-65535
SC.OVRLOAD#
n
Overload
FS+2%, FS+1D, FS+9D, FS
Table 9-3. SCALES Serial Commands