82
920i
Installation Manual
10.1.1
Option Card Diagnostic Errors
Option cards are detected by the
920i
at power-up. If
the current indicator conÞguration requires an option
card but that card is not detected at power-up, an error
similar to the following is displayed:
HARDWARE CRITICAL TO PROPER OPERATION
WITH CURRENT CONFIGURATION
CANNOT BE FOUND
A/D SLOT 4 CHANNEL 1
INSTALL HARDWARE OR RECONFIGURE
To recover from this error you can do the following:
¥
If the option is required, ensure that the card is
properly seated in its slot and cycle the power. If
the card is still not recognized, replace the card
or try installing the card in a different slot
¥
Enter setup mode and reconÞgure to eliminate
the requirement for the option.
¥
Go to the VERSION menu and use the
Reset
Config
softkey (or RESETCONFIGURATION
command) to perform a conÞguration reset.
ConÞguration reset will return all conÞguration
values to their factory defaults.
See Section 10.1.2, below, for information about using
the HARDWARE serial command to verify that
installed cards are recognized.
10.1.2
Using the HARDWARE Command
The HARDWARE serial command can be issued to
verify that all installed cards are recognized by the
system. The HARDWARE command returns a string
of single-digit card codes, representing cards installed
in slots 1Ð14:
HARDWARE=3,3,2,4,5,0,0,0,0,0,0,0,0,0
Table 10-2 lists the card codes returned by the
HARDWARE command.
If an installed card is not recognized (HARDWARE
command returns a code of
0
for that slot), ensure that
the card is seated properly. Reinstall the card, if
necessary, then cycle the indicator power to read the
conÞguration again. If the card is still not recognized,
try installing it in another slot.
10.1.3
User Program Diagnostic Errors
Faulty user programs can cause critical errors that are
detected by the
920i
at power-up. The following error
message is caused by a user program attempting to
divide by zero:
A CRITICAL USER PROGRAM ERROR
HAS BEEN DETECTED
DIVIDE BY ZERO
SYSTEM RESET IS REQUIRED
To recover from this error you can do the following:
¥
Cycle the indicator power to reset the user
program.
¥
Correct the
iRite
program to eliminate the divide
by zero operation. Recompile the program, then
download the corrected program to the indicator.
If technical assistance is required, contact RLWS
technical support.
Diagnostic Boot Procedure
If a user program causes an error in the start-up
handler, the only way to Þx the error is to perform the
following diagnostic boot procedure.
1. Disconnect power to the
920i
.
2. Connect the serial port of a PC with
iRev
installed to port 2 of the
920i
. Connection
must be made at 38400 bps.
3. Open the indicator enclosure and place a
jumper across the SW1 boot mode pins (see
Figure 2-4 on page 6).
4. Power up the
920i
. The indicator will stall at
the diagnostic monitor.
5. Start
iRev
and enter monitor mode, then type
BOOT
.
6. Use the indicator setup switch to enter setup
mode.
7. Remove the jumper from SW1.
8. From monitor mode, enter the
RESETCONFIGURATION command.
Determine the cause of the startup handler error, make
program corrections, then reload the corrected user
program and test.
Code
Card Type
0
No card installed
1
Dual-Channel Serial Expansion Card
2
Dual-Channel A/D Card
3
Single-Channel A/D Card
4
Analog Output Card
5
24-Channel Digital I/O Expansion Card
6
Pulse Input Card
7
1 MB Memory Expansion Card
8
Bus Card
Table 10-2. HARDWARE Command Option Card Type
Codes