![Rice Lake IQ plus 2100 Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/rice-lake/iq-plus-2100/iq-plus-2100_installation-manual_1454163037.webp)
32
IQ plus 2100 Installation Manual
5.1.5
Normal Mode Commands
The serial transmit weight data commands (see Table 5-8) transmit data to the serial port on demand. The transmit
weight data commands are valid only in normal operating mode.
5.2
Saving and Transferring Data
Connecting a personal computer to the
IQ plus 210
EDP port allows you to save indicator configuration data to the
PC or to download configuration data from the PC to an indicator. The following sections describe the procedures
for these save and transfer operations.
5.2.1
Saving Indicator Data to a Personal Computer
Configuration data can be saved to a personal computer connected to the EDP port. The PC must be running a
communications program such as PROCOMMPLUS
®
.
When configuring the indicator, ensure that the values set for the BAUD and BITS parameters on the SERIAL
menu match the baud rate, bits, and parity settings configured for the serial port on the PC.
To save all configuration data, send the DUMPALL EDP command to the indicator. The
IQ plus 210
responds by
sending all configuration parameters to the PC as ASCII-formatted text.
5.2.2
Downloading Configuration Data from PC to Indicator
Configuration data saved on a PC or floppy disk can be downloaded from the PC to an indicator. This procedure is
useful when a number of indicators with similar configurations are set up or when an indicator is replaced.
To download configuration data, connect the PC to the EDP port as described in Section 5.2.1. Place the indicator
in setup mode and use the PC communications software to send the saved configuration data to the indicator. When
transfer is complete, calibrate the indicator as described in Section 4.0 on page 27.
• Calibration settings are included in the configuration data downloaded to the indicator. If the receiving indicator is a
direct replacement for another IQ plus 210 and the attached scale is not changed, recalibration is not required.
• When downloading configurations that include changed serial communications settings, edit the data file to place the
serial communications changes at the end of the file. Communication between the PC and indicator will be lost once the
indicator receives settings for baud rate (BAUD parameter) or data bits and parity (BITS parameter) that do not match
those configured for the PC.
Command
Description
Values
DIGIN1
DIGIN2
Digital input function
OFF, ZERO, UNITS, PRINT
Table 5-7. DIG IN EDP Commands
Command
Description
Response Format
SX
Start serial streaming
OK
or
??
EX
Stop serial streaming
OK
or
??
RS
Reset system
—
XG
Transmit gross weight in displayed units
nnnnnn UU
where
nnnnnn
is the weight value,
UU
is the units.
XGL
Transmit gross weight in pounds
XGK
Transmit gross weight in kilograms
XGO
Transmit gross weight in ounces
XGG
Transmit gross weight in grams
XGC
Transmit gross weight in pounds and ounces
XE
Query system error conditions
nnnnn nnnnn
Table 5-8. Normal Mode EDP Commands