Parameter Setup
15
5.1
Parameters
Function
Sub Function
Description
P0 CHK
SET H
Set High Limit
SET LO
Set Low Limit
BEEP
Set beep mode
• no – beep off for checkweighing
• OK – beep when weight between hi and low
• ng – beep when weight out of hi-low range
P1 REF
AZN 0
Auto zero tracking range: 0.5d, 1d, 2d, 4d
0AUTO
Auto zero range when enabled: 0%, 2%, 5%, 10%, 20%, 50%, 100%
0RAGE
Manual zero range with press of the ZERO key: 0%, 2%, 4%, 10%, 20%, 50%, 100%
0-TARE
Auto zero tracking in net mode (after a tare, the net weight is zero), ON/OFF
SPEED
Set the ADC speed: 7.5/15/30/60 times/second
ZERO
Set zero point. After setting this value, when in zero point, the reading will be –xxx.xxx
P2 COM
MODE
Set RS-232 communication mode:
• CONT (continuously send)
• ST1: send one frame data after stable
• STC: send data continuously when stable
• PR1: press print key to send one frame data (printer mode)
• PR2: press M+ key to send print data and M+ at the same time
• AUTO: auto accumulate (auto print) mode, when weight stable and then return to zero.
Indicator will do accumulate and print operate automatically
• ASK: ask mode, bi-direction
• Command R: read data
• Command T: tare
• Command Z: zero
• Wireless: wireless mode
Note: if you have selected the wireless model, the communication mode has to be set to wireless.
BAUD
Sets the baud rate, 600/1200/2400/4800/9600
pr
Sets the parity verify, 7E1/7O1/8N1
ptype
tpup: set the printer as tpup model
lp-50: set the printer as LP-50 model
lab
Lab x: set gross/acc print format
prt
prt: set the date/time print format
lang
eng: set the print langrage as English.
chn: set the print langrage as Chinese.
P3 CAL
DECI
Select the decimal point location: 0, 0.0, 0.00, 0.000
Dual ON/OFF
INC – Selects the division: 1, 2, 5, 10, 20, 50, 100, 200
CAP – Shows xxxxxx for setting the capacity
CAL
Nonlin – Non- linearity Calibrate
Liner – Linearity Calibrate
COUNT
This display will show xxxxxx for indicating the internal counts
gra
Set gravity.( 9.000~10.000)
P4 OTH
LOCK
Enable/disable key lock
ANM
Animal Weigh Mode: ON/OFF
P5 unt
Lb/lb-ounce/tj/hj
Set units – Tj and Hj cannot be used at the same time
P6 xcl
External calibration.
P7 rst
Reset parameters to the factory settings
P8 uwb
Set Bluetooth function: on/off. When the Bluetooth® function is on, RS-232 cannot be used
Table 5-1. Parameter Settings