Installation

© Rice Lake Weighing Systems

 

 All Rights Reserved

5

2.0

Installation

This section describes procedures for setting up the FlexWeigh System 101 to weigh.

Use a wrist strap to ground yourself and protect components from electrostatic discharge (ESD) when working 

inside the indicator enclosure.
The supply cord serves as the power disconnect for the unit. The power outlet supplying the indicator must be 

installed near the unit and be easily accessible.
The FlexWeigh System 101 has no on/off switch. Before opening the unit, ensure the power cord is 

disconnected from the power outlet.

2.1 Unpacking and Assembly

Immediately after unpacking, visually inspect the unit to ensure all components are included and undamaged. 
The shipping carton should contain the FlexWeigh System 101 unit and this manual. If any parts were damaged in shipment, 

notify Rice Lake Weighing Systems and the shipper immediately. 

2.2 Enclosure Disassembly

The FlexWeigh System 101 must be opened to install option cards and to connect cables for installed option cards.
Ensure power to the indicator is disconnected, then open the enclosure.

2.3 Cable Connections

The FlexWeigh System 101 provides eleven cord grips for cabling into the indicator. The parts kit includes cord grip plugs to 

prevent moisture from entering the enclosure. Install these plugs into all cord grips that will not be used in your application. 

Use the cable grounding instructions for wiring into the indicator.
 

Figure 2-1. Block Wiring Diagram

An additional adhesive label (PN 121108) is included in the parts kit and can be installed at the installer’s discretion 

indicating correct terminal block numbering.

CAUTION

WARNING

Fuse F1 and F2 = 3.15 AMPS SLO-BLO (5X20MM)

Note

Содержание FlexWeigh System 101

Страница 1: ...FlexWeigh System 101 Basic Filler Version 1 02 Operation Manual June 10 2020 PN 120491 Rev C...

Страница 2: ...marks of their respective companies All information contained within this publication is to the best of our knowledge complete and accurate at the time of publication Rice Lake Weighing Systems reserv...

Страница 3: ...rounding 7 2 5 Parts Kit Contents 7 2 6 Option Cards 8 3 0 Setup Menu 9 3 1 Entering the Setup Menu 9 3 2 Setting the System Time and Date 10 3 3 Modifying the Setup Password 11 3 4 Enabling Disabling...

Страница 4: ...exWeigh System 101 ii Visit our website www RiceLake com Rice Lake continually offers web based video training on a growing selection of product related topics at no cost Visit www ricelake com webina...

Страница 5: ...as been read and all instructions are understood Failure to follow the instructions or heed the warnings could result in injury or death Contact any Rice Lake Weighing Systems dealer for replacement m...

Страница 6: ...tal and total registers Transmitted audit trail Digital I O board Relay rack and SSR relay outputs Fast feed Slow feed Fill complete optional Zero tolerance optional The iRite program and source code...

Страница 7: ...ll process This requires that the E Stop button is in a stopped position Resume Starts the fill process from a paused state This requires that the E Stop is in a run position Manual Allows manual cont...

Страница 8: ...or entry into the setup menu Setting the password to nothing will cause the system to not prompt for a password when the Setup Menu softkey is pressed Enabling Disabling ID 1 ID 1 This allows the oper...

Страница 9: ...n the FlexWeigh System 101 unit and this manual If any parts were damaged in shipment notify Rice Lake Weighing Systems and the shipper immediately 2 2 Enclosure Disassembly The FlexWeigh System 101 m...

Страница 10: ...es are 18 AWG unless otherwise specified Figure 2 3 Wiring Diagram Inside Enclosure See Figure 5 3 on page 26 for wiring part numbers Note A B Detail A Detail B Inside Enclosure To Terminal Block R To...

Страница 11: ...Part No Description Qty 14626 Kep nuts 8 32NC 6 6 15133 Lock washers No 8 type A 6 6 15631 Cable ties 4 single A D 6 dual A D 4 15665 Reducing glands for 1 2 NPT cord grips 11 11 15887 6 position scre...

Страница 12: ...2 2 Option Card Locations Slot Bit Type Function 0 1 Programmability E Stop 0 2 Start 0 3 Resume 0 4 Reset 0 5 6 Off Currently not used 2 1 Output Fast Fill 2 2 Slow Fill 2 3 Fill Complete 2 4 Zero T...

Страница 13: ...the entered value against the system password and performs one of the following actions If the password is valid the Setup Menu Main Screen displays Figure 3 2 If the password is invalid Invalid pass...

Страница 14: ...date 3 Press the Enter key to save the settings Figure 3 4 Time and Date Main Screen The Cancel softkey can be pressed at any time to exit this sequence without saving any changes 04 27 2011 02 15PM S...

Страница 15: ...d to verify 5 Re enter the password and press the Enter key again The system performs one of the following actions If the passwords match the system displays Password Changed If the passwords do not m...

Страница 16: ...eeds Use the following steps to modify the filling speeds 1 From the Main Setup Menu Screen Figure 3 7 press the Setup Password softkey a password is not required 2 Press the More softkey to access th...

Страница 17: ...s of operation Figure 3 9 Auto Print Disabled Softkey 3 8 Delay After Discharge Use the following steps to modify the delay after discharge 1 From the Main Setup Menu Screen Figure 3 7 on page 12 cycl...

Страница 18: ...tional output Slow Fill By pressing the Slow Fill softkey the digital I O is tested and the Slow Fill icon on the setup menu screen is darkened while it s being tested Press the Slow Fill softkey agai...

Страница 19: ...enu Screen 1 Press the Presets softkey Softkeys in Figure 4 2 are displayed Figure 4 2 Presets Softkey Parameters 2 Press the corresponding softkey to edit the data Parameters that can be edited inclu...

Страница 20: ...t the cycle switches from Fast Feed to Dribble Feed 1 Enter the dribble weight using the arrow keys and the numeric keypad 2 Press Enter on the 920i to save that value The existing number needs to fir...

Страница 21: ...ue before the FlexWeigh System 101 will start a batch 1 Enter the preact weight using the arrow keys and the numeric keypad 2 Press Enter on the 920i to save that value The existing number needs to fi...

Страница 22: ...onsecutive Number Print Sub Total Print Total Consecutive Number Press the Consecutive Number softkey to enter the next number to be weighed The system keeps incrementing every time a batch is running...

Страница 23: ...ey Figure 4 7 on page 18 to access the Print Total softkey 2 Press the Print Total softkey to access the following screen Figure 4 10 Clear Total Screen 3 Press the Yes softkey to clear the total and...

Страница 24: ...he fast fill and leaves the slow fill on until the target weight preact weight is satisfied Dual Speed Filling Turns on the fast fill until the dribble weight is satisfied The system turns on the slow...

Страница 25: ...er to integrate with the FlexWeigh System 101 is the TMU 220 Tape Printer but will easily integrate with any strip printer Hook up the printer to the FlexWeigh System 101 per printer manual instructio...

Страница 26: ...anel Push Button Includes Manual Fill Maintained Off Spring Return Manual Switches Fill On Jog Fill Fast Slow Optional Front Panel Event Pilot Lights Includes Green Ready Red Fill Complete Amber Filli...

Страница 27: ...Appendix Rice Lake Weighing Systems All Rights Reserved 23 5 3 Product Dimensions Figure 5 1 FlexWeigh System 101 Basic Filler Enclosure Dimensions 14 33 11 00 18 24 18 83 19 63 14 22 6 69 14 00...

Страница 28: ...t Parts Illustration See Detail A 29 27 51 48 30 3 47 98 28 46 13 25 24 69 67 70 13 26 50 99 68 74 16 5 4 53 28 9 13 14 19 20 17 12 11 4 5 44 5 52 18 92 1 4 5 6 23 55 22 105 106 91 90 21 83 78 79 80 7...

Страница 29: ...ingle Channel A D Card 1 48 68724 920i Cover Gasket 1 49 66502 Overlay Membrane Switch 1 50 109549 920i CPU Board Assembly 1 51 15650 Cable Tie Mount 3 4 in 7 52 16861 Label High Voltage 3 53 16892 La...

Страница 30: ...Red Stranded 4 1 2 15432 Wire 18 AWG Brown Stranded 2 5 1 3 15435 Wire 18 AWG Blue Stranded 33 1 4 15451 Wire 18 AWG Yellow Stranded 8 1 5 15431 Wire 18 AWG Black Stranded 2 1 50 109549 920i CPU Board...

Страница 31: ...caused by accident misuse neglect alteration improper installation improper repair or improper testing Rice Lake Weighing Systems shall be the sole judge of all alleged non conformities Such equipmen...

Страница 32: ...QJ VWDQGDUG V RU RWKHU UHJXODWLRQV GRFXPHQW V HXWVFK LU HUNOlUHQ XQWHU XQVHUHU DOOHLQLJHQ 9HUDQWZRUWXQJ GDVV GLH 3URGXNWH DXI GLH VLFK GLHVH UNOlUXQJ EH LHKW GHQ IROJHQGHQ 1RUPHQ XQG 5HJXOLHUXQJVEHVWL...

Страница 33: ......

Страница 34: ...anada Mexico 800 321 6703 International 715 234 9171 Europe 31 0 26 472 1319 Rice Lake Weighing Systems is an ISO 9001 registered company Rice Lake Weighing Systems Specifications subject to change wi...