Communication
13
Example 1: Transmit all data (without additional parity)
Net Weight = 3.46
Tare Weight = 1.200 Weight Status: stable
Scale No. = 100
Weight Unit = kg
Status Flag: 0x42
Weight Condition Flag: 0x42
0
1
0
0
0
0
1
0
By ASCII Code:
0x42
0x42
0X42
0X0d
0x30
0x30
0x30
0x33
0x2e
0x34
0x35
0x36
06b
0x67
0x0d
0x34
0x30
0x30
0x31
0x2e
0x32
0x30
0x30
0x6b
0x67
0x0d
0x0a
Example 2: Transmit only Net weight (without Header Code)
Net weight = 3.456
Note
Specifications must be set to satisfy this condition. See Section 2.3 on page 9.
Example 3: Weight is overflow data
Net weight = OF
Weight Condition Flag
Bit
Data Description
Not Used
Bit 7
Not Used, always 0
Fixed to 1
Bit 6
Fixed to 1
Not Used
Bit 5
Not Used
Weight UF
Bit 4
1 when weight underflow, 0 when not
Weight OF
Bit 3
1 when weight overflow, 0 when not
Negative Net Weight
Bit 2
1 when net weight is negative, 0 when not
Weight Stable
Bit 1
1 when weight is stable, 0 when not
Zero Sign
Bit 0
1 when weight zero sign is set, 0 when not
Table 3-4. Weight Condition Flags
0
1
0
0
0
0
1
0
0x30
0x30
0x33
0x2e
0x34
0x35
0x36
0x0d
0x0a
0x20
0x20
0x20
0x20
0x4f
0x46