![Rice Lake DIGI DSX-1000 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/rice-lake/digi-dsx-1000/digi-dsx-1000_operation-manual_1454154013.webp)
Setup
9
2.3
Communication Settings
Use the following steps to configure communication settings on the
DIGI DSX-1000
.
1. Press
to enter mode selection.
2. Press
to enter specification settings.
3. Press
or
to access each specification.
4. Press the option desired for each specification. See Table 2-1.
5. Press
Table 2-1. Specifications (SPEC 141)
Spec. No.
Bit 3
Bit 2
Bit 1
Bit 0
0
RS-232C PC Protocol (Bit 3,2,1,0)
0000 - Inhibit 0001 - stream type
0010 - manual type 0011 - command type
0100 - DS470 manual 1 0101 - DS470 manual 2
1
RTS/CTS handshaking (Bit 3)
0 - On
1 - Off
Baud Rate of RS-232C (Bit 2,1,0)
000 - 4800 bps 001 - 9600 bps
010 - 19200 bps 011 - 38400 bps
2
Stop bit of RS-232C (Bit 3)
0 - 1 bit
1 - 2 bit
Data length of RS-232C (Bit 2)
0 - 7 bit
1 - 8 bit
Parity of RS-232C (Bit 1,0)
00 - None
01 - Odd
10 - Even
3
Interval of Time out error of RS232C (Bit 3,2)
00 - 1 second
01 - 3 second
10 - 5 second
11 - 10 second
Transmission
condition of RS232-C
(Bit 1)
0 - Weight Stable
1 - Unconditional
Additional parity
code in text of RS-
232C (Bit 0)
0 - No
1 - Yes
4
Tare Weight in text of RS-
232C (Bit 3)
0 - No
1 - Yes
Weight unit RS-232C (Bit 2)
0 - Allow
1 - Inhibit
Header Code in text of
RS-232C (Bit 1)
0 - No
1 - Yes
STATUS data in
text of RS-232C
(Bit 0)
0 - No
1 - Yes
5
One touch tare printing (Bit 3)
0 - No
1 - Yes
Set Point Type (Bit 2)
0 - Act low
1 - Act high
Sequence number
print (Bit 1)
(not available)
0 - No
1 - Yes
Use Internal Printer
(Bit 0)
(not available)
0 - No
1 - Yes
6
Buzzer (Bit 3)
0 - On
1 - Off
Set Point Alarm (Bit 2,1)
00 - On (Under/Over)
10 - Off
Set Point Output (Bit 0)
0 - On
1 - Off
7
Print the status against the
target range (Bit 3)
(not available)
0 - No
1 - Yes
When stable and weight
change >= 10 e, RS-232 stream
type output once (Bit 2)
0 - On
1 - Off
RS232C data length of output
weight data (Bit 1)
0 - 7 byte fixed
1 - actual length
8
Weight check bar display when negative weight (Bit 3)
0 - Allow
1 - Inhibit
twice to return to the weigh mode.