8
DC-782 Operation Manual
going into the normal weighing mode.
•
If SPEC 20, Bit 2 is set to 1: Standard, the scale’s display will test the LCD segments for each
numeral from 0 to 9, asterisks, decimal points and annunciators before going into the normal
weighing mode.
2.4.3
Battery Charging
A fully charged battery allows for approximately 300 hours of continuous use (with the backlight off). When the
battery is low the battery indicator light will light up. It will take approximately 12-14 hours to fully recharge a
battery that has been completely dissipated. To charge the battery, plug in the AC power cord.
2.4.4
Start-Up Screens
1. If SPEC 20, Bit 3 - Version Display When Power On is set to
0: Allow
, the scale will display the current
version of the firmware it is using as it powers up (For further instructions on how to set the
specifications, see Section 3.2.1).
2. After a test of the different elements of the display, the scale takes you to the stand-by screen in the
Weighing Mode. SPEC 20, Bit 2 - Selection of Segment-Check Style controls whether the startup test of
the segments is Fast or Standard. At the stand-by screen the
QUANTITY, WEIGHT,
and
UNIT WEIGHT
displays show zeroes.
From this stand-by screen all of the basic weighing, counting and inventory operations can be performed
3. If there is anything on the platform(s) and it exceeds the scale start range, the display will show the error
message
OF
indicating “weight overflow”.
Note:
The Initial Start Range settings are controlled by SPEC 20, Bit 1. The default setting is 0: ± 10% OF FULL SCALE.
If this error appears, remove the weight from the platform and the scale will continue its startup
sequence.