background image

BenchMark

®

 HE-X

Hostile Environment Extreme Bench Scales

Technical Manual

 

PN 198967 Rev B

May 19, 2020 

Содержание BenchMark HE-X

Страница 1: ...BenchMark HE X Hostile Environment Extreme Bench Scales Technical Manual PN 198967 Rev B May 19 2020...

Страница 2: ...marks of their respective companies All information contained within this publication is to the best of our knowledge complete and accurate at the time of publication Rice Lake Weighing Systems reserv...

Страница 3: ...alling 715 234 9171 and asking for the training department 1 0 Introduction 1 1 1 Safety 1 2 0 Installation 2 2 1 Unpacking 2 2 2 Leveling the Scale 2 2 3 Connecting the Load Cell Cable 2 2 4 Groundin...

Страница 4: ...BenchMark HE X ii Visit our website www RiceLake com Rice Lake continually offers web based video training on a growing selection of product related topics at no cost Visit www ricelake com webinars...

Страница 5: ...ould result in damage to equipment or corruption to and loss of data General Safety Do not operate or work on this equipment unless this manual has been read and all instructions are understood Failur...

Страница 6: ...e scale top cover and locate the level bubble 3 Adjust the four corner feet on the scale base until the level bubble and all feet contact the support surface so the scale does not rock 4 Lock the jam...

Страница 7: ...ral weights are used distribute them evenly around the platform 3 Perform a calibration 4 Remove certified calibration weights and check the zero reading If necessary repeat the calibration process Se...

Страница 8: ...HE X 4 Visit our website www RiceLake com 2 7 Replacement Parts See the following information for replacement parts details Figure 2 2 Parts Illustration 18 14 1 17 19 8 7 20 15 16 11 10 12 9 13 8 16...

Страница 9: ...Load Cell SPT RLPCBC 60 100 lb Scale 87023 Load Cell SPT RLPCBC 60 150 lb Scale 87024 Load Cell SPT RLPCBC 60 200 lb Scale 87024 Load Cell SPT RLPCBC 60 250 lb Scale 87024 Load Cell SPT RLPCBC 60 300...

Страница 10: ...remains at zero Incorrect load cell cable connections Faulty indicator Service indicator Erratic weight displays on indicator Vibration near the scale Remove the source of the vibration or adjust digi...

Страница 11: ...457 mm x 133 mm 18 75 476 mm 18 75 476 mm 100 lb 50 kg 150 lb 75 kg 200 lb 100 kg 250 lb 125 kg 300 lb 150 kg 500 lb 250 kg 1000 lb 500 kg 50 lb 25 kg 18 x 24 x 5 25 457 mm x 610 mm x 133 mm 18 75 47...

Страница 12: ...a wrench 6 The load cell and cable can now be removed from scale 7 Thread cable of replacement load cell through the scale frame as the unit arrived 8 Position load cell on shim and screw in four low...

Страница 13: ...ion of such equipment by RLWS confirms that the nonconformity actually exists and was not caused by accident misuse neglect alteration improper installation improper repair or improper testing RLWS sh...

Страница 14: ...18 18 x 24 24 x 24 Rated Output 0 91 mV V Maximum Overload 150 200 capacity dependent Overload Protection Five point independently adjusted Cable Length 10 3 m 6 wire shielded Output Impedance 1000 no...