![Rice Lake 65059 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/rice-lake/65059/65059_installation-manual_1453835009.webp)
Mechanical Installation
©
Rice Lake Weighing Systems
●
All Rights Reserved
5
2.2
Mount Installation
Use the following steps to install the RL50210 TA/65059. The figures are typical load cell
mount installations for the 50-250 and 500 lb configuration.
Figure 2-2. 50-250 lb Installation
Figure 2-3. 500 lb Installation
The type of installation, vessel support structure and the surface the mount is to be placed
on, determines the method of locating, attaching and assembling the RL50210 TA/65059.
Carefully consider the following three areas that commonly cause accuracy problems:
• It is important the supporting legs are adequately braced so they do not spread when
the system is fully loaded
• Make sure the supporting structure has the necessary strength to prevent excessive
deflection when the system is fully loaded
• Check to see if there is any attached equipment such as skirting, venting or piping
which is likely to cause binding or lack of flexibility
Plain Washer
Type B Plain Washer
Loading Spacer
Flex Lock Nut
Base Plate
Cantilever Beam Load Cell
Deflection Spacer
Lock Washer
Socket Head Load
Cell Screws
Top Plate
Neoprene Mount
Socket Head Cap Screw
Top Plate
Flat Washer
Loading Spacer
Machine Screw
Overload Stop
Socket Head
Set Screw
Nylon Plug
Base Plate
Shear Beam Load Cell
Socket Head Cap Screw
Lock Washer
Flat Washer
Lock Washer
Socket Head Load
Cell Screws
Neoprene Mount
Deflection
Spacer