590AG Animal Weigher Indicator Operation Manual
2.3.2
Load Cells
To attach cable from a load cell or junction box, remove connector J1 from the board. The connector plugs into a
header on the board. Connect cable from the load cell or junction box through the load cell cable cord grip to
connector J1 as shown in Table 2-1. If using 6-wire load cell cable (with sense wires), remove jumpers JP1 and JP2
before reinstalling connector J1 (see Figure ). For 4-wire installation, leave jumpers JP1 and JP2 on.
When connections are complete, reinstall connector J1 on the board.
SHIELD wire connection is not used. Use grounding procedure described in Section 2.3.1.
For 6-wire connections, remove jumpers JP1 and JP2.
Figure 2-3. Scale/Indicator System Connection
2.3.3
Serial Communications
To attach serial communications cables, remove connector J2 from the board (see Figure 2-4). Connect
communications cable through cord grip to connector J2 as shown in Table 2-2.
Once cables are attached, reconnect J2 to the header on the board.
The
590 AG Indicator
serial port supports full duplex RS-232 communications for connections to printers, PCs,
and other attached devices. See Section 3.0 for general configuration information; see Section 3.2.4 for serial port
configuration.
J1 Pin
Function
1
+SIG
2
–SIG
3
+SENSE
4
–SENSE
5
SHIELD (see NOTE below)
6
+EXC
7
–EXC
Table 2-1. J1 Pin Assignments
J2 Pin
Function
1
RS-232 TxD
2
RS-232 Ground
3
RS-232 RxD
Table 2-2. J2 Pin Assignments
Note
D
A
B
Indicator
A
D
C
B
Scale
A -EXC Black
B +SIG Green
C +EXC Red
D -SIG White
Connector
C