5.2 Communication Protocols

The scale has two communication protocols, escape and maintenance protocol.

5.2.1 Escape Protocol

An escape protocol is where the escape (0X1B or ASCII 27) is used to indicate that there is a command following. On the PC 

side there must be a listener created by the vendor that will interpret this protocol. This listener must also take care of all the 

issues regarding data integrity to make sure that the data that was sent and received is valid. 
Two examples include:

• Scale initiated communication
• PC initiated communication

The escape protocol commands table shows (below) what can be sent across communications lines.

ESC characters that will be used is shown below.

PC Initiated

ESC Value

Request current values/settings

R

Diagnostics

A

Send scale control messages

C

PC Initiated

ESC Value

Send single reading

R

Send diagnostic response

Table 5-2.  Escape Protocol Commands

Name

ESC 

Character

ESC Value with 

Parameters

Description

Reading

R

R

Tells PC the scale is sending a reading; immediately following this is the value that is sent 

Example: <ESC><R>ESC><W0200.0<ESC>Nm<ESC>E

Weight

W

Wnnn.n

The patient weight (

Example: W02000 means 200.0

). If scale is overloaded or under loaded,  

999.99 is returned

Height

H

Hnnn.n

Patient height

BMI

B

Bnn.n

Patient BMI

Units

N

Nc

Indicates the units the values have been taken (

m=metric, c=constitutional

).

End of Packet (EOP)

E

E

Indicates the end of the command has been reached.

Diagnostics 

(request)

A

Accc

A request for a diagnostic test on certain parts of the scale (like battery life, load cells).

Diagnostics 

(response)

Z

Zccc

The response of the diagnostics done on the scale; values include error codes to indicate an 

issue, or all zeros (Z000) to indicate the scale is performing properly

Control (set a value)

C

Cccc=c

Sets the value of the scale’s global settings 

Example: <ESC><CUOM=m><ESC><E sets the unit of measurement

Table 5-3.  ESC Characters

Name of Control

Identifier

Unit

Unit of Measure (metric or constitutional)

UOM

c (m or c)

Table 5-4.  Scale Global Values and Identifiers

Содержание 150-10-6

Страница 1: ...150 10 6 Digital Physician Scale Waist Level Software Version 11525 Technical Manual PN 162342 Rev B August 18 2022...

Страница 2: ...respective companies All information contained within this publication is to the best of our knowledge complete and accurate at the time of publication Rice Lake Weighing Systems reserves the right to...

Страница 3: ...ing or obtained by calling 715 234 9171 and asking for the training department Revision History This section tracks and describes the current and previous manual revisions for awareness of major updat...

Страница 4: ...Connections 6 2 5 Leveling the Scale 6 3 0 Operation 7 3 1 Weighing 8 3 2 Hold Release Function 8 3 3 Using the Body Mass Index BMI Function 8 3 4 Troubleshooting 9 4 0 Configuration 10 4 1 General N...

Страница 5: ...is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful i...

Страница 6: ...t the scale while someone is on the scale Do not allow minors children or inexperienced persons to operate this scale Do not use in the presence of flammable materials Do not use this product if any o...

Страница 7: ...back Damage caused by improper packaging is not covered by the warranty 2 2 Scale Assembly Use the following steps to set up the scale A Phillips head screwdriver will be needed for installation 1 Pla...

Страница 8: ...attach the column to the scale base as shown in Figure 2 3 Figure 2 3 Attach With Screws 2 2 1 Wheel Assembly Attach the wheel assembly to the scale prior to connecting the second column To attach th...

Страница 9: ...lumn 2 Once the cable is connected place the upper column onto the lower column aligning the screw holes Ensure the cable does not get pinched Figure 2 6 Insert Upper Column into Lower Column 3 Secure...

Страница 10: ...gure 2 8 Rice Lake Weighing Systems offers optional AC adapters utilizing an adapter not supplied by Rice Lake Weighing Systems voids all warranties Figure 2 8 Power Connection 2 5 Leveling the Scale...

Страница 11: ...ff the scale A second press releases the weight value Not active while in BMI mode BMI Pressing the BMI key enables access to the BMI Body Mass Index mode defaults when scale is turned on The patient...

Страница 12: ...to zero Pressing prior to the patient getting on the scale will also hold the weight display 3 3 Using the Body Mass Index BMI Function Use the following steps in determining the BMI LB Mode 1 Ensure...

Страница 13: ...le E4L BAT Battery low but still usable one bar left on indicator display E4U Battery low and unstable no bars left on indicator display E11 CAL Calibration Error recalibrate scale Err 1 Load cell cab...

Страница 14: ...Press to enter a displayed menu and or parameter Press or to scroll through values Press to save the displayed selection and move to the next parameter 4 1 2 Enter Numbers Press to enter parameter va...

Страница 15: ...cated in the back of the scale to enter the setup parameters for the scale Use a small paper clip small screwdriver or other similar object to press the setup switch 4 Once the setup switch is pressed...

Страница 16: ...6 Use the Up Down arrow keys to increment decrement numbers 7 When done press ENTER key to move to the next parameter LOAD LOAD This is the amount of weight applied during calibration Can also be chan...

Страница 17: ...umeric value and ARW If you do not want to change this value press the BMI key to move to the next setting Example from ARW to SAL If you want to change the value use the following steps 1 Press ENTER...

Страница 18: ...een a numeric value and ATOUT If you do not want to change this value press the BMI key to move to the next setting If you want to change the value use the following steps 1 Press ENTER key to change...

Страница 19: ...ant to change this value press the BMI key to move to the next settings If you want to change the value use the following steps 1 Press ENTER to change parameters 2 Use the Up Down arrow keys to selec...

Страница 20: ...e back of the scale to enter the setup parameters for the scale Use a small paper clip small screwdriver or other similar object to press the setup switch on the back of the indicator under the cover...

Страница 21: ...le until ID flashes 2 Press Press to access the test menu 3 Continue to press to scroll through the various menu items 4 Once complete press until Done displays 5 Press to start the weighing process F...

Страница 22: ...as the weight was either in motion or out of range If displaying weight and not BMI the scale will send out the following 21 character string xxxxxxxxx SP uu SP mmmmm SP CR LF Table 5 1 Print Format T...

Страница 23: ...rotocol Commands Name ESC Character ESC Value with Parameters Description Reading R R Tells PC the scale is sending a reading immediately following this is the value that is sent Example ESC R ESC W02...

Страница 24: ...D Z Zero the scale F Show flash values used for the first flash process L USB On Off not available on USB communication Table 5 5 Maintenance Protocol Commands Escape Protocol Example 1 Escape Protoco...

Страница 25: ...the use of the USB driver Driver protections may need to be temporarily disabled on Windows 10 or later computers to allow for the installation of the USB driver 1 Connect the scale s indicator to a P...

Страница 26: ...personnel Go through the following steps for basic maintenance Check the overall appearance of the entire scale for any obvious signs of damage Inspect the condition of the AC power adapter cord for...

Страница 27: ...table baud rate default 9600 8 bits No parity 1 stop bit No handshaking Environmental Operating Temperature 50 F to 104 F 14 C to 40 C Storage Temperature 32 F to 158 F 0 C to 70 C Humidity 85 relativ...

Страница 28: ...150 10 6 Digital Physician Scale 24 Visit our website www RiceLake com...

Страница 29: ......

Страница 30: ...54868 USA U S 800 472 6703 Canada Mexico 800 321 6703 International 715 234 9171 Europe 31 0 26 472 1319 Rice Lake Weighing Systems Specifications subject to change without notice www ricelake com PN...

Отзывы: