Appendix
97
Where:
<STX> STX character
<P> Polarity
<W7> Seven characters of net data with decimal pt
<U> Units
<M> Mode
<S> Status
<CR> Carriage return
Note that industrial serial scales (IND SC) do not require the <M>, <U> and <S> identifiers. However, the units
and number of decimal places must be specified. Units can be selected from the FORMAT menu; decimal places
should be indicated with a w-spec identifier. For example, a seven-digit weight reading requiring two decimal
places should be specified as <W7.2> rather than <W7>.
To change or match formats, use the same path to change formats.
9.9
Regulatory Mode Functions
The function of the front panel
TARE
and
ZERO
keys depends on the value specified for the REGULAT parameter
on the FEATURE menu. Table 9-5 describes the function of these keys for the NTEP, CANADA, OIML, and
NONE regulatory modes.
TARE
and
ZERO
key functions are configurable when the REGULAT mode is set to
INDUST (see Table 9-6 on page 97).
Table 9-5. TARE and ZERO Key Functions for REGULAT Parameter Settings
REGULAT
Parameter Value
Weight on Scale
Tare in System
Front Panel Key Function
TARE
ZERO
NTEP
zero or negative
no
no action
ZERO
yes
CLEAR TARE
positive
no
TARE
yes
TARE
CANADA
zero or negative
no
no action
ZERO
yes
CLEAR TARE
positive
no
TARE
yes
no action
OIML
zero or negative
(not to exceed -20dd)
no
no action
ZERO
yes
CLEAR TARE
ZERO
and
CLEAR TARE
positive
no
TARE
ZERO
yes
TARE
ZERO
and
CLEAR TARE if weight is
within ZRANGE.
No action
if weight is outside of
ZRANGE
NONE
zero or negative
no
TARE
ZERO
yes
CLEAR TARE
positive
no
TARE
yes
CLEAR TARE
Table 9-6 lists the subparameters available when configuring a scale using INDUST mode. The table includes the
default values of the INDUST subparameters and the effective (not configurable) values used by the NTEP,
CANADA, OIML, and NONE regulatory modes.
REGULAT / INDUST Parameter
REGULAT Mode
Parameter Name
Text Prompt
INDUST
NTEP
CANADA
OIML
NONE
SNPSHOT
Display or Scale weight source
DISPLAY
DISPLAY
DISPLAY
DISPLAY
SCALE
ZTARE
Remove tare on ZERO
NO
NO
NO
YES
NO
KTARE
Always allow keyed tare
YES
YES
NO
YES
YES
MTARE
Multiple tare action
REPLACE
REPLACE
NOTHING
REPLACE
REMOVE
NTARE
Allow negative tare
NO
NO
NO
NO
YES
Table 9-6. REGULAT / INDUST Mode Parameters, Comparison with Effective Values of Other Modes
Содержание 118788
Страница 1: ...Counterpart Counting Scale Indicator Version 2 5 User Manual 118677 Rev E...
Страница 2: ......
Страница 6: ...iv Counterpart Counting Scale Indicator...
Страница 26: ...20 Counterpart Counting Scale Indicator Figure 2 22 Counterpart Assembly and Components...
Страница 27: ...Installation 21 Figure 2 23 Counterpart Dimensions Figure 2 24 Counterpart Rear and Side Dimensions...
Страница 111: ......