- The discharge hose (not supplied) must have a minimum diameter of 25 mm and must be rigid 
and kink resistant to prevent crushing. 
- To avoid leakages in the delivery line and get the best performance, ensure to seal the fittings 
with Teflon. 
 

Remarks: - All components of the discharge line must be compression-proof. 

- All components of the discharge line must be professionally installed 
- If the components are not compression-proof or if they are improperly installed, the pressure 
line could burst during operation. Risk of injury from liquid spurting out! 

 

4.4- Start-up 

1. The pump must be installed in a vertical position: ensure that it is stable during operation. 
2. The suction holes must never be obstructed. It is therefore preferable that the pump should never be 
placed directly on the ground or on the bottom of the well, pond or vessel. 
For example, use a brick to support the pump. 

 
 
V. OPERATION

 

 
5.1- Intended use 

1. This clear water pump is a submersible pump intended for domestic use. 
The pump is not intended for artisanal, industrial and/or commercial uses (for ex. Public parks, sports 
grounds …) 
2. The pump is designed for routine household uses such as gardening, irrigation systems, pumping water 
from tanks, well... 
It can be used to suck up clear water from flooded premises with particles in suspension that are less than 
[see table II] in diameter. When used to dry out premises (for ex. cellar draining) it is recommended to 
place the pump below floor level. 

3. The pump is fully submersible: the immersion depth must not exceed [see table II]. 

4. The pump should not be used for: 

- for sucking up liquids or materials that are corrosive, flammable/combustible, explosive r any other 
dangerous liquid; fats, oils, sea water, dirty water and waste water (e.g. from toilet, industrial…)   
- for swimming pool cleaning; in fountains or aquariums… 

- for pumping or transferring water intended for human consumption or any other food liquids. 
5. The pump must not be used for operations not described in this manual. 
Any other use, other than that described in the instructions, is likely to damage the pump and to put the user 
in serious danger. 

6. The temperature of clear water sucked up should not exceed 35°C. 

 

5.2- Operation - automatic functioning mode 

Connect pump to mains power. 
As this pump is an automatic water pump, it starts operating as soon as it is connected to the electricity 
supply, even when there is no water.   
 

Содержание 511696

Страница 1: ...PUMP 1200W WITH INTEGRATED AUTOMATIC CONTROL FLOAT SWITCH User and maintenance manual IT POMPA MULTICELLULARE SOMMERGIBILE 1200W CON CONTROLLO AUTOMATICO GALLEGIANTE INTEGRATI Manuale di istruzioni e...

Страница 2: ...mpes ne sont pas destin es pomper de l eau potable I NOMENCLATURE 1 Poign e 2 C ble d alimentation 3 Connecteur 4 Port sortie refoulement 5 Corps de pompe 6 Trous d aspiration Fig 1 II CARACTERISTIQUE...

Страница 3: ...e l environnement de l aire de travail Garder l aire de travail bien clair e lumi re naturelle ou artificielle suffisante Garder l aire de travail bien ventil e Ne pas utiliser le produit s il y a ris...

Страница 4: ...ion de rallonge Lorsque le produit est utilis avec une rallonge n utiliser que des rallonges con ues et pr vues pour supporter le courant alimentant le produit 16 Rester vigilant Surveiller ce que vou...

Страница 5: ...ment vers l appareil ou d autres composants lectriques Danger de mort par lectrocution 9 Placer la rallonge de telle mani re qu elle ne puisse entrer en contact avec un quelconque liquide 10 Ne pas in...

Страница 6: ...en vigueur et par du personnel qualifi En cas de doute nous vous conseillons de vous adresser un lectricien La canalisation fixe laquelle sera raccord e la pompe doit comporter un dispositif de s para...

Страница 7: ...st une pompe submersible destin e un usage domestique Elle n est pas pr vue pour des applications artisanales industrielles et ou commerciales par ex dans des parcs publics terrains de sport 2 La pomp...

Страница 8: ...e pression La pompe commence fonctionner lorsque elle est reli e l lectricit si de l eau est toujours d tect e apr s 10 secondes la pompe continuera de fonctionner Lorsque la pression de la pompe atte...

Страница 9: ...lectrique Le flotteur ne d marre pas V rifier l alimentation lectrique Mettre le flotteur en position haute Pas de d bit Filtre sale ou port d aspiration obstru Tuyau de refoulement pli Nettoy le fil...

Страница 10: ...ce of swimming pools This pump is not intended for pumping drinking water I PARTS LIST 1 Handle 2 Power cord 3 Connector 4 Discharge port 5 Pump body 6 Suction port Fig 1 II CHARACTERISTICS Descriptio...

Страница 11: ...ent Keep work area well lit natural light or sufficient artificial lighting Keep work area well ventilated Do not use product where there is risk to cause fire or explosion in the presence of flammabl...

Страница 12: ...common sense Do not operate product when you are tired under the influence of alcohol prescription medicines or drugs 17 Check damaged parts Before further use or reuse of the product it should be car...

Страница 13: ...e 12 As a general rule repairs are only to be carried out by an electrician If repairs are performed improperly there is danger of liquid getting into the electronic components of the device 13 Symbol...

Страница 14: ...milar qualification in order to avoid any danger a Make sure that the power supply corresponds with the connection specifications of the device see rating label b Check that the power cable is not dam...

Страница 15: ...rounds 2 The pump is designed for routine household uses such as gardening irrigation systems pumping water from tanks well It can be used to suck up clear water from flooded premises with particles i...

Страница 16: ...re setting the internal pump pressure is lower than 1 5 bar the pump starts operating again Warning Never operate the pump without water dry running The pump is not designed for continuous operation e...

Страница 17: ...sieve Clean pump and replace worn out parts Pump switches of after short operating period Dirty water thermal cut out stops pump Water too hot thermal cut out stops pump Remove mains plug Clean pump a...

Страница 18: ...pa non prevista per il pompaggio dell acqua di consume I ELENCO COMPONENTI 1 Maniglia 2 Cavo elettrico 3 Connettore 4 Bocca di scarico 5 Corpo pompa 6 Fori di aspirazione Fig 1 II CARATTERISTICHE Desc...

Страница 19: ...Il disordine nell area di lavoro aumenta il rischio di incidenti 2 Tenere conto dei fattori circostanti di influenza Accertarsi che l illuminazione sia buona luce del sole o illuminazione artificiale...

Страница 20: ...pportare la corrente che alimenta l attrezzo 16 Fare sempre attenzione Guardare quello che si fa Procedere con giudizio Non utilizzare l utensile se non si concentrati si stanchi o sotto l influenza d...

Страница 21: ...e la macchina se persone o animali sono in acqua o in contatto con i tubi 11 Non lasciare incustodito l apparecchio Scollegare l alimentazione durante i periodi di non utilizzo o durante una lunga ass...

Страница 22: ...e sostituito dal costruttore dal personale del relativo servizio di post vendita o da personale con qualifiche simili per evitare qualunque tipo di rischio a Verificare che l alimentazione di rete cor...

Страница 23: ...mestico La pompa non destinato ad applicazioni artigianli industriali e o commerciali ad esempio nei parchi pubblici campi sportivi 2 La pompa progettata per l utilizzo domestico quotidiano in applica...

Страница 24: ...ore 5 2 2 Pressione La pompa inizia a funxionare quando collegata all elettricit se viene ancora rilevato acqua dopo 10 secondi la pompa funzioner Quando la pressione della pompa raggiunge l impostaz...

Страница 25: ...e elettrica Il galleggiante non si avvia Controllare l alimentazione elettrica Mettere il galleggiante in posizione alta Nessuno scarico Filtro o fori di aspirazione intasato Tubo di scarico piegato P...

Отзывы: