19
19
G
B
POINT A -
ELECTRIC CONNECTIONS
DO NOT REMOVE ANY JUMPER!
OTHERWISE THE OPERATOR WILL NOT WORK!
Radio Antenna
Close limit-switch that cuts off the motor in closing
Open limit-switch that cuts off the motor in opening
Limit-switch common contact
Pedestrian opening contact (NO)
Main power supply 230 Vac 50/60 Hz (120V/60Hz upon request)
Connection of the earth line
Built-in radio module (model CRX),
or connector for radio receiver RIB, 24Vdc supply
24Vdc safety strip self-test power supply
Accessories power 24Vdc
Accessories power supply -24Vdc
Common contact (common line for all the command and safety inputs) (+)
Single pulse contact (NO)
Photocells contact (NC)
Safety strip contact (NC)
Buzzer contact (24Vdc max 200 mA) (-)
Flashing light (max 40W )
Motor common connection
Motor phase and capacitor connections
Temperature sensor cable connection PROBE (Code ACG4665 optional)
Electronic regulator for low speed on approach
Electronic torque regulator
J1
J2
J3
J4
J5
J6
J7
J8
R1
R2
AERIAL
LSC
LSO
COM
PED BUTT
L-N
EARTH
RADIO
A+ TEST
A+
A-
COM +
K BUTT.
PHOT.
EDGE
-
U - MOTOR
V-W - MOTOR
PROBE
TRIMMER LOW SPEED
TRIMMER TORQUE
J4
J7
R1
J3
J6
J8
J5
J2
R2
J1