34
IN CASE OF ISSUES
SYMPTOM
CHECK
All the LEDs on the MASTER NO TOUCH 868 are turned off
Check the voltage is 12 or 24 V
to the terminal of the supply POWER of the MASTER NO
TOUCH 868
Only the LED DL2 is on
- No safety devices are set up. Perform the photocells NO TOUCH 868 set up.
OR
- The safety device of the pedestrian door is active. Close the pedestrian door in the main door.
When giving a command the buzzer emits 2 tones
- Autotest failed. Check the connections between the MASTER and the control panel, set JP1
and then press the S1 PROG RX pushbutton for a moment or remove and restore the power
to the installation.
During the set up of the safety devices the buzzer emits 3 tones
You are attempting to set up the safety device of the pedestrian door before the NO TOUCH
868. Set up the NO TOUCH 868 photocell first.
When giving a command the buzzer emits 4 tones
Wires not connected between the output blinker on the control panel and the MASTER NO
TOUCH 868. Connect them and then press the S1 PROG RX pushbutton for a moment or
remove and restore the power to the installation.
The door stops and the buzzer emits 4 tones
There is the presence of vibrations from the accelerometer because of strong wind or the door
is stimulated manually.
When giving a command the door tends to open, then closes and the buzzer emits 5 tones
Failure on NO TOUCH 86 receiver.
Give a new command.
If the problem persists, deactivate the accelerometer.
If it still persists replace the receiver of the NO TOUCH 868 photocell.
When giving a command the door tends to open or close, then stops and the buzzer emits a
continuous tone for 10 seconds and the led DL1 turns orange.
- Supervision failed. MASTER NO TOUCH 868 does not receive a response from the photocell,
possibly caused by metallic obstacles which prevent radio communication.
- Check the MASTER NO TOUCH 868 has not been installed in a metallic container. If necessary
connect an external 868,3 MHz antenna (code ACG5451) to the metallic container.
The buzzer emits a tones every 3 seconds during door operation for 1 minute and the bi-
colour LED DL1 turns fixed red.
Replace the batteries of the photocell as soon as possible as they are low.
The door does not move, the buzzer emits an alternate tone for 1 minute and the bi-colour
LED DL1 turns alternate red-green.
Replace the batteries of the photocell as they are dead.
The door does not open or close and the bi-colour LED DL1 turns green.
Photocell is not aligned or engaged or the battery is dead on the NO TOUCH 868 photocell
transmitter.
ACCESSORIES
RED RADIO TRANSMITTER
for contact (not supplied) pedestrian door.
3 x AA 1,5V alkaline batteries needed (not included)
code ACG6202
LITHIO AA BATTERIES
for NO TOUCH 868 photocells- 2 x 3,6V
code ACG9517
G
B