VERTIGO Wi-Fi in combination with the electronic device MASTER Wi-Fi conforms to standard
EN13849-2 (2008) and when used with a RIB electronic control panel it is a Class 2
protection device for protecting persons/things from collisions caused by mechanical moving
parts such as automatic gates or doors.
The obstacle is detected for the whole distance between the infrared transmitter and receiver
which constitute the VERTIGO Wi-Fi product.
VERTIGO Wi-Fi can be positioned anywhere without needing to use electrical wire.
The Wi-Fi system (made up of a VERTIGO Wi-Fi and MASTER Wi-Fi) operate at a frequency
of 868,3 MHz.
The MASTER Wi-Fi board communicates constantly with VERTIGO Wi-Fi and always indicates
interruptions of the infrared signal between the TX transmitter and the RX receiver or any
type of malfunctioning.
Each VERTIGO Wi-Fi has its own internal ID code that distinguishes it from the other devices.
The Wi-Fi system is an active security system because it constantly verifies proper functioning
of the VERTIGO Wi-Fi devices and battery condition.
When using RIB electronic control panels you can run auto-tests on the system.
With RIB actuators, RIB electronic control panels having the auto-test function and RIB safety
devices you can create an installation that conforms to the European Directives and Norms
in force.
After completing the system, you must make sure it conforms to standard EN13241-1.
RIB shall not be liable for any damages caused by improper, incorrect or unreasonable use
of the product.
REFERENCE TO STANDARDS FOR AUTOMATIC GATES AND DOORS
RIB MAY NOT BE HELD RESPONSIBLE FOR DAMAGES CAUSED BY IMPROPER, WRONG
OR UNREASONABLE USE.
Usage restrictions:
The VERTIGO Wi-Fi photocells cannot be used on devices excluded by
the application of the EN12978, such as:
- Protection devices for the installation on doors used for a different purpose to those ones
used for pedestrian or veheicle access, covered by the norm which principal intent is that
of allowing a safe access to industrial, commercial, public and commercial sites. Some
examples of excluded accesses can be: sluice gates, dams, lift doors, vehicles’ doors,
doors used mainly to restrain animals, theatre curtains, railways barriers, barriers used
only for vehicles.
- Devices used only fo the standard control and for the stopping, including the emergency
stopping, of motorized doors.
- Safety systems and safety devices used on machineries different from doors.
ATTENTION:
Any possible modification of the device, or of the configuration of the same
cannot be carried out without the clear authorization by the manufacturer or, by the local
authorized dealer.
The installer of the safety device must make sure that the end user know the following:
- That the safety devices must be made known to all appropriate people.
- That the passages to reach the devices must be kept clear from any obtsacle.
- About the procedures for cleaning so to avoid the dangerous building up of material.
- The possible details for a restart of the system after an emergency or accidental stop caused
by the control system.
Any modification of the project or, of the configuration of the device, without discussing it
first with the manufacturer or with the local autorized dealer can cause dangerous situations.
VERTIGO Wi-Fi PHOTOCELLS ARE ONLY ON DURING DOOR OPERATION. THANKS TO THE
SLEEP MODE. WHEN THE DOOR IS NOT MOVING THE PHOTOCELLS ARE OFF TO ALLOW
FOR LONGER BATTERY LIFE.
VERTIGO Wi-Fi are produced in wall-type versions:
- VERTIGO Wi-Fi 8
code ACG8042
- VERTIGO Wi-Fi 10
code ACG8043
to be fasten to the primary and/or secondary borders (mobile or fixed) made of iron or other
smooth material.
It is possibile, if necesary, to rotate by 90° in
90° only the ray direction in respect to the
main structure that contains the circuit (see
picture here aside).
APPLICATION
MAX
GATE
WEIGHT
MAX
DISPLACEMENT
SPEED
VERTIGO Wi-Fi 8
150 kg
300 kg
13 m/min.
10 m/min.
VERTIGO Wi-Fi 10
500 kg
1000 kg
13 m/min.
10 m/min.
RX
TX
50
35 **
*
REGULA
TOR
Y LIMIT
MOUNTING
VERY IMPORTANT!
When installing the VERTIGO
Wi-Fi photocell, besides following
the instructions in the chapter
“APPLICATION”, verify that when using
a NOT RIB control panel, this one must
be complying with the reaction time
(inversion) requested by the Norm
EN12453 (requirements of safety
devices used on motorized gates/
doors).
PLACE THE RECEIVER OF THE
PHOTOCELL ON THE TOP OF THE LEAF
AND THE COLUMNS OF THE GATE AND
IN FULL VIEW OF THE Wi-Fi MASTER
BOARD.
THE VERTIGO Wi-Fi TRANSMITTER
MUST BE APPLIED TO THE BOTTOM
OF THE LEAF AND THE COLUMNS OF
THE GATE.
NO OBSTACLES SUCH AS WALLS,
PILLARS OR METAL CABINETS MUST BE
PRESENT BETWEEN THE RECEIVER OF
THE VERTIGO Wi-Fi PHOTOCELLS AND
THE MASTER Wi-Fi BOARD.
If it is not possible to avoid that
because the obstacles cannot be
removed, please install an 868 MHz
aerial (code ACG5451) on the MASTER
Wi-Fi and position it so to guarantee
a good quality radio communication
between the parts.
This solution also prevents the quick
discharge of the batteries on the
VERTIGO Wi-Fi.
* Before fastening the base of the RECEIVER
to the upper part of the leaf, check for
possible obstructions due to potential
stops and/or conveying systems.
** Available space for potential mechanical
stop.
Measurements in mm
Содержание ACG8042
Страница 30: ...30 NOTES ...
Страница 31: ...31 NOTES ...
Страница 32: ...32 ...
Страница 33: ...33 ...
Страница 34: ...34 ...