14
G
B
TECHNICAL DATA / INSTALLATION
TOUCH Wi-Fi in combination with the electronic device MASTER Wi-Fi conforms to standard
EN13849-2 (2008) and when used with a RIB electronic control panel it is a Class 2
protection device for protecting persons/things from collisions caused by mechanical moving
parts such as automatic gates or doors. The obstacle is detected along the entire length of
the device axially and perpendicularly.
The TOUCH Wi-Fi strips can be positioned anywhere without needing to use electrical wire.
The WiFi system (made up of a TOUCH Wi-Fi and MASTER Wi-Fi) operate at a frequency
of 868,3 MHz.
The MASTER Wi-Fi card communicates constantly with the TOUCH Wi-Fi strips and always
signals collisions or malfunctions.
Each TOUCH Wi-Fi has its own internal ID code that distinguishes it from the other devices.
The WiFi system is an active security system because it constantly verifies proper functioning
of the TOUCH Wi-Fi devices and battery condition.
When using RIB electronic control panels you can run auto-tests on the system.
With RIB actuators, RIB electronic control panels having the auto-test function and RIB
safety devices you can create an installation that conforms to the European Directives and
Norms in force.
After completing the system, you must make sure it conforms to standard EN13241-1.
RIB shall not be liable for any damages caused by improper, incorrect or unreasonable use
of the product.
ATTENTION:
If you remove the power of the MASTER Wi-Fi for a long time, the TOUCH Wi-Fi
safety strips and the NOVA Wi-Fi photocells will exhaust faster than normal the
charging of their batteries. Keep the MASTER Wi-Fi always properly fed to ensure
a period of three years for the batteries-life, as stated by RIB.
If for instance, the power to the system is cut off every night, the photocells
and the safety strips will regularly and constantly search for the MASTER Wi-Fi
without finding it. Therefore, the life span of the batteries may be reduce to less
than one year.
Any possible modification of the device, or of the configuration of the same cannot be carried
out without the clear authorization by the manufacturer or, by the local authorized dealer.
The installer of the safety device must make sure that the end user know the following:
-
That the safety devices must be made known to all appropriate people.
-
That the passages to reach the devices must be kept clear from any obtsacle.
-
About the procedures for cleaning so to avoid the dangerous building up of material.
-
The possible details for a restart of the system after an emergency or accidental stop
caused by the control system.
Any modification of the project or, of the configuration of the device, without discussing it
first with the manufacturer or with the local autorized dealer can cause dangerous situations.
ELECTRICAL CONNECTIONS
BAT
Alkaline batteries 3 x 1.5V (type AA code ACG9519)
SW2
Microswitches for combination and identification
J3
Terminals for connecting to mechanical strip contact
S2 PROG. TX
Programming pushbutton
DL1 (red)
Radio transmission signal
DL1
SW2
BAT
J3