29
TABLE SUMMARISING VISUAL AND SOUND ALARMS
SIGNALS DURING PROGRAMMING SEQUENCE
EVENT
BUZZER STATUS
FLASHER STATUS
DL1 LED STATUS
Dip 1 ON (hold-to-run mode)
Or failure of a safety device
Off
Off
Flashes on-off 250 ms
Dip 2 ON (full stroke programming)
Off
Off
Flashes on-off 500 ms
Dip 2>1 ON (pedestrian stroke programming)
Off
Off
Flashes on-off 500 ms
Programming sequence stopped due to intervention of a safety
device
10 seconds tone with 2 seconds pause
Off
On steady
EVENT
BUZZER STATUS
FLASHER STATUS
DL12 LED STATUS
No transmitter code entered
Off
Off
Flashes intermittently red/green
Dip 1 > 2 - transmitter code programming for full opening
Off
Off
Flashes red for 10 seconds
Dip 1 > 3 - transmitter code programming for pedestrian
opening
Off
Off
Flashes green for 10 seconds
Dip 1>2> 3 - transmitter code programming for R-AUX relay
Off
Off
Flashes orange for 10 seconds
Correct transmitter codes programming for full opening and
R-AUX relay
1 Tone
Off
Turns green once
Correct transmitter codes programming for pedestrian opening
1 Tone
Off
Turns red once
Remote control code not present in memory
Off
Off
Red flash
Memory saturated by remote control codes (1000 codes saved)
Off
Off
Runs 6 green flashes
Radio code deletion for full opening, pedestrian opening, R-AUX
relay
2 Tones
Off
Runs 2 green flashes
WARNING SIGNALS DURING OPERATION
EVENT
BUZZER STATUS
FLASHER STATUS
LED STATUS AND SIGNAL OUTPUT
Stop button pressed
Off
Off
Led DL6 turns off
Photocell intervention
1 Tone
Off
Led DL7-8 turns off
Edge intervention
2 Tones
Off
Led DL9-10 turns off
Intervention of impact sensor
3 Tones
Off
No led combined
Failure of a safety device or safety device engaged for too long
Off
Off
Led DL1 flashes on-off 250 ms
Running with emergency batteries (24 vdc)
Off
Currently enabled
Signal output flashes on-off twice for 250 ms
followed by a pause of 2 seconds
Emergency batteries low signal
1 Tone every 5 seconds for 1 minute
(It is renewed by giving a command)
Off
Signal output flashes continuously on-off for 500
ms
Operation with emergency batteries charged by solar panels
Off
Off
Signal output flashes on-off 3 times for 250 ms
followed by a pause of 2 seconds
Alarm from edge
2 Tones every 5 seconds for 1 minute
(It is renewed by giving a command)
Enabled for 1 minute
No led combined
Impact sensor alarm
3 Tones every 5 seconds for 1 minute
(It is renewed by giving a command)
Enabled for 1 minute
No led combined
Failed photocells auto-test alarm
4 Tones every 5 seconds for 1 minute
(It is renewed by giving a command)
Off
No led combined
Functional block activated by smartphone
Off
Off
Led DL12 is steady on green.
Achievement of set cycles
6 Tones every 5 seconds for 1 minute
(It is renewed by giving a command)
Off
No leds matched
Energy saving activated by smartphone
Off
Off
Blue led flashes once every 5 seconds
G
B