In|Sync Thermal Camera Installation Guide v1.0
6
test, insert into the network port.
7. Pull the power cable through the gland. Remove ¼” of insulation from the end of the
wire. Use size 3 slotted screwdriver to connect the DC power wires to the green connector,
following the steps below:
a. Connect the +24 VDC wire to the leftmost terminal (wire color black in the picture)
b. Connect the DC GND wire to the rightmost terminal (wire color white in the picture)
c. Connect the green connector to the camera.
Note:
Your wire may be Red (+24 VDC), Black (DC Ground), and White (chassis ground).
In either case, +24 VDC goes to the leftmost terminal and DC ground goes to the rightmost
terminal, when viewed from behind the camera.
Fig. 7 Power cable pulled through gland
Fig. 8 Power wires connected to terminals
8. On the safety ground wire, remove ¼” of insulation and attach a spade terminal.
Loosen the nut in the corner with pliers and insert the spade terminal to ground the power cable
to the camera chassis. Tighten the nut on the spade terminal with pliers.
9. Insert the rubber seal back into the gland housing. This can be difficult. The best
approach is to work a small section at a time, gradually moving around the rubber seal, until the
entire rubber seal is inserted.