RHINO PIRW3 Скачать руководство пользователя страница 4

 

 

PIRW3

 

1. Introduction 

 

The Rhino PIRW is a high quality infrared body movement sensor, which 
is battery operated and communicates with a compatible Rhino receiver via 
radio frequency (RF) transmission. This detector is easy to install, provides 
excellent detection sensitivity and has a long battery life (approximately 3 
years). This sensor can transmit four different codes to the receiver: 
 

• 

Alarm – sent when a valid movement is detected 

• 

Tamper – sent when the detector case is opened 

• 

Supervision – sent every 2 ½ hours to the receiver  

• 

Low Battery – sent when the batteries need replacing 

 

1.1. Important notes 

 

• 

NEVER touch the pyro sensor 

 
 
 

• 

During the warm up period, (first 3 minutes after installing the 
batteries) the detector will not respond to the tamper switch or 
to movement in front of the detector. You must wait 3 minutes 
before it will respond properly. 

 

• 

This detector has Intelligent Power Saving (IPS). This means 
that in normal operation the lights will not flash every time you 
move in front of the detector. When the red light flashes on for 
1 second, this means that the detector has picked up and 
validated body movement (or an intruder) and an alarm code is 
transmitted. The detector will now go into IPS mode for 
approximately 3 minutes. During this time the detector will not 
trigger and no lights will turn on (see section 4 for more 
information).   

Содержание PIRW3

Страница 1: ...r u c t i o n s RhinoCo Technology ABN 74 001 621 610 Head Office 9 Hannabus Place McGraths Hill NSW 2756 AUSTRALIA Ph 61 2 45 774708 Fax 61 2 45 774885 Sales Office 223 Ramsay St Haberfield NSW 2045...

Страница 2: ...2 PIRW3 BLANK PAGE...

Страница 3: ...ing Operation 8 4 1 Test Mode 8 4 2 Intelligent Power Saving IPS Normal Operation 9 4 3 Adjusting the Sensitivity 9 4 4 Dual Edge Sensing DES technology explained 10 4 5 The Tamper Switch 13 4 6 Low b...

Страница 4: ...acing 1 1 Important notes NEVER touch the pyro sensor During the warm up period first 3 minutes after installing the batteries the detector will not respond to the tamper switch or to movement in fron...

Страница 5: ...to clean the battery terminal or where the terminal meets the battery If all the plastic has been cleared and the detector is still not responding then remove the battery which the plastic was coveri...

Страница 6: ...removing the piece of plastic from under one of the battery terminals During this period the detector will not respond and should be left untouched until the 3 minute period is up 3 minutes after pow...

Страница 7: ...ou have chosen adjust the angle of the sensor slightly re test You will find that a slight up down angle change may improve catch performance significantly Mount the detector on your wall using the sw...

Страница 8: ...mode as its name implies is used for testing the detection range and testing the radio transmission back to the receiver To place the detector in test mode do the following Remove the front cover The...

Страница 9: ...anytime after the 3 minutes of IPS then it will go back into IPS mode again for 3 minutes and so on There is no need for the detector to trigger more than once every 3 minutes as your alarm system sho...

Страница 10: ...walk into or out of an infrared beam zone this will be sensed and processed by the DES technology built into the detector The red trigger light will not turn on until the detector has made a valid mov...

Страница 11: ...default and the body moves from position 1 to position 4 within 10 seconds then the detector will have received 3 pulses in 10 seconds This means the detector will have made a valid movement detectio...

Страница 12: ...pplies if the body moves in the opposite direction 2 No trigger body movements No trigger body movements are body movements which are too small to be recognized as valid body movements to trigger the...

Страница 13: ...ow battery voltage then the red light will flash an additional 6 times in a row The sensor will send a low battery radio transmission to your receiver The batteries should be replaced immediately The...

Страница 14: ...top terminal is pressing down firmly on top of each battery Just after each battery is replaced the lights will begin flashing 6 times to confirm the detector is now powered The warm up period now ap...

Страница 15: ...iver Even if the signal path has been recently checked during a weekly test blockage can occur if a metal object is moved into the path A user may not be able to reach a panic or emergency button quic...

Страница 16: ...ee from defects in materials and workmanship under normal use and service for twelve months from the date of original purchase Sellers obligation shall be limited to repairing or replacing at its opti...

Отзывы: