The electrical connection must be made according to local regulations. Ensure
that
the
power supply
corresponds to the value given on the
appliance
dataplate.
Install a suitable circuit breaker
which
must be exclusively used for this
purpose.
Make
sure that the electrical systems are suitably earthed.
On the back of
the
appliance
there is a terminal marked with the symbol (see Pict.
1),
which is pro
-
vided for equipotential connection between different appliances
(see electrical
safety standards).
FOR APPLIANCES USING A THREE-PHASE POWER SUPPLY,
FOLLOW THE INSTRUCTIONS AND WIRING DIAGRAM ATTACHED
TO THE APPLIANCE.
CHECK CORRECT MOTOR
ROTATION.
pict. 1
Electrical connection
All Rhima warewashing
appliance
s are pre-wired and supplied complete with
connecting cable and appropriate plug.
This cable should be connected to a
separate power supply by means of an isolator or appropriate plug and socket and
in such a way that a safe and trouble-free use of the
appliance
is guaranteed.
This
appliance
MUST be earthed
.
The heating element of the built-in rinse water booster and the heating element of
the washtank are often interlocked.
The booster has priority over the washtank,
the two heaters will never switch on simultaneously.
To comply with local health authorities
appliance
s may have a thermostop, this device
prevents the
appliance
from operating until correct temperatures have been reached.
Ventilation
Ensure there is adequate room for ventilation. Exhaust must be according to local
regulations.
7