Figure 10: Digital Outputs
Connect the output of the RHE to the load. Connect the other side of the load to either GND or
to the positive supply rail. With a grounded load, the output current should be limited to 20mA
(480mW at 24V). With a load connected to the positive supply rail the output can drive up to
100mA (2.4W at 24V).
The output can drive relays directly as well. Relays should be connected between the output and
the positive supply rail.
3.2.3.1.2
Intrinsically safe Digital Outputs
NOTE: Intrinsically safe I/O circuits must only be operated with certified barriers or isolating
amplifiers
The RHE21 can be supplied with up to two intrinsically safe digital outputs.
Outputs DO1 and DO2 are universal outputs and can be used as frequency, pulse or
control/status outputs.
As a standard the outputs are floating open collector outputs.