5. Push and hold the engine control switch in the
START
position until the engine starts. Once the
engine starts, release the engine control switch; the
switch will automatically move into the
RUN
position.
Engine Control Switch
6. As the engine starts and stabilizes, gradually move
the choke lever back to the
OFF
position.
STOPPING THE GENERATOR
Normal Operation
During normal operation, use the following steps to stop
your generator:
1. Remove any connected loads from the control
panel receptacles.
2. Allow the generator to run at “no load” to reduce
and stabilize engine and alternator temperatures.
3. Push the engine control switch to the
OFF
position.
4. Turn the fuel shutoff valve to the
OFF
position.
During an Emergency
If there is an emergency and the generator must be
stopped quickly, push the engine control switch to the
OFF
position immediately.
Engine Control Switch
MAINTENANCE CHART
WARNING
Stop the engine before starting maintenance work.
NOTICE:
Use only specified genuine parts for replacement. Ask an authorized dealer for further
information.
Table 1: Maintenance Schedule - Owner Performed
Maintenance
Item
Before Every
Use
After First 20
Hours or First
Month of Use
After 50 Hours
of Use or Every
3 Months
After 100 Hours
of Use or Every
6 Months
After 300 Hours
of Use or Every
Year
Engine Oil
Check Level
Change
Change
–
–
Cooling
Features
Check/Clean
–––
–
Air Filter
Check
–
Clean
1
–
Replace
Spark Plug
–
–
–
Check/Clean
Replace
Spark Arrestor
–
–
–
Check/Clean
–
1
Service more frequently if operating in dry and dusty conditions.
Fuel
Check
level
–
–
–
–
Table 2: Maintenance Schedule - Authorized Rheinland Elektro Maschinen Service Dealer Performed
Maintenance
Item
Before Every
Use
After First 20
Hours or First
Month of Use
After 50 Hours
of Use or Every
3 Months
After 100 Hours
of Use or Every
6 Months
After 300 Hours
of Use or Every
Year
Valve Clearance
–––
–
Check/Adjust
Fuel Filter
–
–
–
Check/Clean
–
Idle Speed
–––
–
Check/Adjust
–
–
–
–