CONNECTIONS – ELECTRICAL
44
The power consumption of the water heater is:
Component
Power
consumption
Comments
Solar controls
14 Watts
Constant load
4 Watts differential controller
6 Watts solenoid valve
4 Watts timer
Solar circulator
36 Watts
Maximum load at solar heating cycle start up
30 Watts
Average load during the solar heating cycle
The water heater will only operate on a sine wave at 50 Hz. Devices generating
a square wave cannot be used to supply power to the water heater.
WIRING DIAGRAMS
A double pole isolating switch
must be incorporated in the
fixed wiring, according to the
AS/NZS 3000, AS 5601 and
local authority requirements.