INSTALLER TIPS

MINIMUM AND MAXIMUM VENT LENGTHS

POWER VENT

Max Vent Length (Eq. Ft.) Rigid Pipe Diameter

INLET MODELS

2" (5 CM)

3" (8 CM)

4" (10 CM)

Inlet

Outlet

Inlet

Outlet

Inlet

Outlet

GHE80SU-130(A)

GHE80SU-160(A)

1 (0.31 m)

20 (6.1 m)

1 (0.31 m)

135 (41.1 m)

1 (0.31 m)

185 (56.4 m)

GHE80SU-200(A)

N/A

N/A

GHE80SU-300(A)

GHE100SU-130(A) 

GHE100SU-160(A)

1 (0.31 m)

20 (6.1 m)

GHE100SU-200(A)

GHE100SU-250(A) 

N/A

N/A

GHE100SU-300(A)

GHE100SU-350(A)
GHE100SU-400(A)

1 (0.31 m)

65 (19.8 m)

1 (0.31 m)

100 (30.5 m)

Min Vent Length (Eq. Ft.) Rigid Pipe Diameter

All applicable models 

1 (0.31 m)

15 (4.6 m)

1 (0.31 m)

15 (4.6 m)

1 (0.31 m)

15 (4.6 m)

All venting lengths shown are for up to 8000 ft altitude. See the Use and Care Manual for models with altitudes above, and/or inlet/outlet specs for models with 6" vent lengths.

MINIMUM AND MAXIMUM VENT LENGTHS

POWER DIRECT VENT

Max Vent Length (Eq. Ft.) Rigid Pipe Diameter

INLET MODELS

2" (5 CM)

3" (8 CM)

4" (10 CM)

Inlet

Outlet

Inlet

Outlet

Inlet

Outlet

GHE80SU-130(A) 
GHE80SU-160(A)

20 (6.1 m)

20 (6.1 m)

60 (18.3 m)

75 (22.9 m)

120 (36.6 m)

135 (41.1 m)

GHE80SU-200(A) 

N/A

N/A

GHE80SU-300(A)

GHE100SU-130(A) 
GHE100SU-160(A)

20 (6.1 m)

20 (6.1 m)

GHE100SU-200(A) 
GHE100SU-250(A) 

N/A

N/A

65 (19.8 m)

75 (22.9 m)

120 (36.6 m)

135 (41.1 m)

GHE100SU-300(A)

65 (19.8 m)

75 (22.9 m)

120 (36.6 m)

135 (41.1 m)

GHE100SU-350(A) 
GHE100SU-400(A)

50 (15.2 m)

65 (19.8 m)

70 (21.4 m)

85 (25.9 m)

Min Vent Length (Eq. Ft.) Rigid Pipe Diameter

All applicable models 

5 (1.5 m)

15 (15.2 m)

5 (1.5 m)

15 (15.2 m)

5 (1.5 m)

15 (15.2 m)

All venting lengths shown are for up to 2000 ft altitude. See the Use and Care Manual for models with altitudes above, and/or inlet/outlet specs for models with 6" vent lengths.

Get the unit’s Model and Serial Numbers ready and contact us:

US

 1.800.432.8373 / 

Canada

 1.800.268.6966

Be sure to have your 

Model and Serial Numbers

 before calling  

customer service (located on the water heater’s Rating Label) 

Welcome to the Setup Wizard

This setup wizard will prompt the user to:

Continue

*

 

Set the Time and Date

*

 

Set Schedules for Hours of Operation

*

 

Connect to the Wi-Fi Network

5

FINAL STEPS

Step 5, 

Complete the Setup

Once power is applied to the water heater and the 

‘On’ 

button is pressed, 

the LCD will automatically begin the 

Startup Wizard:

1. Set the Time and Date

2.  Schedule Hours of Operation for the business – Enables Triton to save 

energy and money when the business is not operating

3.  Connect to WiFi – Enables users to receive leak and diagnostic alerts, 

usage reports and more

Follow the 

on-screen instructions

 to complete setup.

•  Remember that the 

condensate trap is part 

of the exhaust tee and 

does not require  

extra plumbing

•   Recommended 

minimum 3" vertical 

drop for every 4 ft. of 

horizontal run 

•  Plumb the condensate 

line for the proper size 

and run to avoid air 

bubbles, which can 

prevent drainage

VENTING (con't)

ELECTRIC CONNECTION

Step 4,

 Connect the Electrical

To ensure proper ignition:
• Ensure all electrical connections are secure

• Use correct polarity

• Connect to a 120VAC – 50/60 Hz power supply

•  Ensure water heater is properly grounded back to  

the main breaker box with minimum 12 gauge

•    Ensure breaker is sized properly for 7 AMP service  

per water heater

4

INSTALLER TIPS

•  Connect the yellow wires 

from the water heater to the 

exhaust pressure switch

•  Connect the white wires 

from the heater to the flue 

temperature sensor

CUSTOMER SERVICE

Have Questions,  

Need Help Troubleshooting?

Switch

Connection

FORM NO. RH-130T • 06/19 • WP