11. FUNCTION SETTINGS
11-1. INDOOR UNIT (Setting by remote controller)
•
The function settings of the control of the indoor unit can be changed by this procedure according
to the installation conditions. Incorrect settings can cause the indoor unit to malfunction.
•
After the power is turned on, perform the Function Setting according to the installation conditions
using the remote controller.
•
The settings may be selected between the following two: Function Number and Setting Value.
•
Settings will not be changed if invalid numbers or setting values are selected.
PREPARATION
• Before turning on the power of the indoor unit:
- Confirm whether the piping air-tight test and vacuuming have been conducted.
- Reconfirm whether there is no miswiring.
• Turn on the power of the indoor units.
FUNCTION SETTING METHOD (for Wireless remote controller)
Entering the Function Setting Mode
• While pressing the POWERFUL button and SET TEMP. (
) simultaneously, press the RESET button to enter the
function setting mode.
STEP 1
Setting the Remote controller Custom code
Use the following steps to select the custom code of the remote controller. (Note that
the air conditioner cannot receive a signal code if the air conditioner has not been set
for the matching custom code.) The custom codes that are set through this process
are applicable only during the Function Setting process. For details on how to set
the custom codes through the normal process, refer to "REMOTE CONTROLLER
CUSTOM CODE SETTING".
1. Press the SET TEMP. ( ) ( ) button to change the custom code between
→
→ →
.
Match the code on the display to the air conditioner custom code. (initially set to )
(If the custom code does not need to be selected, press the MIN. HEAT button and
proceed to
STEP 2
.)
2. Press the MODE button and check that the indoor unit can receive signals at the
displayed custom code.
3.
Press the MIN. HEAT button to accept the custom code, and proceed to
STEP 2
.
The air conditioner custom code is set to "A" prior to shipment.
The remote controller resets to custom code A when the batteries in the remote controller are replaced. If you use a
custom code other than custom code A, reset the custom code after replacing the batteries.
If you do not know the air conditioner custom code setting, try each of the custom codes ( → → →
) until
you find the code which operates the air conditioner.
STEP 2
Selecting the Function Number and Setting Value
1. Press the SET TEMP. ( ) (
) buttons to select the function number.
(Press the MIN. HEAT button to switch between the left and right
digits.)
2. Press the POWERFUL button to proceed to setting the value.
(Press the POWERFUL button again to return to the function number
selection.)
3. Press the SET TEMP. ( ) ( ) buttons to select the setting value.
(Press the MIN. HEAT button to switch between the left and right
digits.)
4.
Press the MODE button, then the START/STOP button in order to fix
the settings.
5.
Press the RESET button to end the function setting mode.
6.
After completing the Function Setting, be sure to turn off the power
and turn it on again.
Function number
Setting
value
CAUTION
After turning off the power, wait 30 seconds or more before turning on it again.
The Function Setting will not become active unless the power is turned off then on again.
Содержание RIWH09AVFJ
Страница 2: ...1 INDOOR UNIT WALL MOUNTED TYPE RIWH09AVFJ RIWH12AVFJ DTR_AS129E_01 2017 01 27 ...
Страница 28: ...2 OUTDOOR UNIT SINGLE TYPE ROSH09AFWJ ROSH12AFWJ DTR_AO230E_01 2017 01 27 ...
Страница 33: ... 02 04 OUTDOOR UNIT ROSH09 12AFWJ OUTDOOR UNIT ROSH09 12AFWJ 3 REFRIGERANT CIRCUIT MODEL ROSH09AFWJ ...
Страница 34: ... 02 05 OUTDOOR UNIT ROSH09 12AFWJ OUTDOOR UNIT ROSH09 12AFWJ MODEL ROSH12AFWJ ...
Страница 35: ... 02 06 OUTDOOR UNIT ROSH09 12AFWJ OUTDOOR UNIT ROSH09 12AFWJ 4 WIRING DIAGRAMS MODEL ROSH09AFWJ ...
Страница 36: ... 02 07 OUTDOOR UNIT ROSH09 12AFWJ OUTDOOR UNIT ROSH09 12AFWJ MODEL ROSH12AFWJ ...
Страница 42: ... 02 13 OUTDOOR UNIT ROSH09 12AFWJ OUTDOOR UNIT ROSH09 12AFWJ 8 2 SOUND LEVEL CHECK POINT 40 in 1m ...