MODEL : ROSH12AFWJ

Содержание RIWH09AVFJ

Страница 1: ...AIR CONDITIONER INDOOR OUTDOOR RIWH09AVFJ RIWH12AVFJ DESIGN TECHNICAL MANUAL ROSH12AFWJ ROSH09AFWJ Wall Mounted type REFRIGERANT R410A INVERTER ...

Страница 2: ...1 INDOOR UNIT WALL MOUNTED TYPE RIWH09AVFJ RIWH12AVFJ DTR_AS129E_01 2017 01 27 ...

Страница 3: ...ERFORMANCE 01 08 5 1 AIR VELOCITY DISTRIBUTION 01 08 5 2 AIR FLOW 01 09 6 OPERATION NOISE SOUND PRESSURE 01 10 6 1 NOISE LEVEL CURVE 01 10 6 2 SOUND LEVEL CHECK POINT 01 11 7 ELECTRICAL CHARACTERISTICS 01 12 8 SAFETY DEVICES 01 13 9 EXTERNAL INPUT OUTPUT 01 14 9 1 EXTERNAL INPUT 01 14 9 2 EXTERNAL OUTPUT 01 16 10 WIRELESS REMOTE CONTROLLER 01 18 11 FUNCTION SETTINGS 01 19 12 OPTIONAL PARTS 01 24 1...

Страница 4: ...in 12 5 8 x 24 13 16 x 13 16 320 630 20 Sub 3 5 16 x 24 13 16 x 1 2 84 630 13 3 Fin pitch FPI Main 23 Sub 18 Rows Stages Main 2 20 Sub 1 4 Pipe type Copper Fin type Aluminum Enclosure Material Polystyrene Color White Approximate color of MUNSELL N9 25 Dimensions H W D Net mm 268 x 840 x 203 in 10 9 16 x 33 1 16 x 8 Gross mm 270 x 884 x 336 in 10 5 8 x 34 13 16 x 13 1 4 Weight Net lbs kg 19 8 5 Gro...

Страница 5: ...09AVFJ RIWH12AVFJ 10 5 8 270 34 1 4 870 8 1 16 204 Outline of unit Unit in mm 10 5 8 270 1 5 16 34 8 9 16 217 8 1 4 209 2 15 16 74 34 1 4 870 16 3 4 426 12 3 16 310 17 1 2 444 6 1 2 165 5 11 16 144 7 178 9 3 16 233 12 5 8 321 12 3 8 315 11 5 8 295 2 9 16 65 for pipe inlet 2 9 16 65 for pipe inlet ...

Страница 6: ...UNTED TYPE RIWH09 12AVFJ WALL MOUNTED TYPE RIWH09 12AVFJ INSTALLATION PLACE Unit in mm 2 45 or more 71 1 800 or more 3 63 or more Outline of unit 1 25 or more 3 52 or more 6 144 or more 60 1 500 or more 4 86 or more ...

Страница 7: ... 01 04 WALL MOUNTED TYPE RIWH09 12AVFJ WALL MOUNTED TYPE RIWH09 12AVFJ 3 WIRING DIAGRAMS MODELS RIWH09AVFJ RIWH12AVFJ ...

Страница 8: ...3 5 46 0 65 9 01 5 90 0 65 9 55 5 87 0 66 10 07 6 24 0 66 104 5 90 4 64 0 51 6 59 4 67 0 52 7 27 5 08 0 53 7 47 5 49 0 53 7 95 5 46 0 54 8 39 5 83 0 54 115 4 20 3 28 0 39 4 67 3 31 0 39 5 12 3 62 0 40 5 29 3 89 0 40 5 60 3 86 0 41 5 94 4 13 0 41 AFR 750 Indoor temperature CDB 17 8 21 1 23 9 26 7 29 4 32 2 CWB 12 2 15 6 17 2 19 4 21 7 22 8 Outdoor temperature CDB TC SHC IP TC SHC IP TC SHC IP TC SH...

Страница 9: ...34 0 96 12 01 7 92 0 96 12 73 7 88 0 97 13 44 8 39 0 98 104 8 05 6 35 0 87 8 97 6 38 0 89 9 89 6 96 0 90 10 20 7 51 0 91 10 78 7 51 0 92 11 40 7 98 0 92 115 5 66 5 15 0 69 6 28 5 19 0 70 6 93 5 63 0 71 7 17 6 11 0 71 7 57 6 07 0 72 8 02 6 48 0 73 AFR 750 Indoor temperature CDB 17 8 21 1 23 9 26 7 29 4 32 2 CWB 12 2 15 6 17 2 19 4 21 7 22 8 Outdoor temperature CDB TC SHC IP TC SHC IP TC SHC IP TC S...

Страница 10: ...15 3 76 0 67 3 67 0 68 3 58 0 70 3 49 0 71 24 18 3 90 0 67 3 81 0 68 3 72 0 69 3 62 0 71 AFR Air flow rate m3 h TC Total capacity kW IP Input Power kW MODEL RIWH12AVFJ AFR 441 Indoor temperature FDB 60 65 70 75 Outdoor temperature FDB FWB TC IP TC IP TC IP TC IP 5 3 10 71 1 09 10 46 1 12 10 20 1 14 9 95 1 16 14 12 12 04 1 13 11 76 1 15 11 47 1 18 11 18 1 20 23 19 13 35 1 18 13 03 1 20 12 71 1 23 1...

Страница 11: ...s m TOP VIEW Vertical airflow direction louver Up Horizontal airflow direction louver Right Left m 0 1 2 3 4 5 6 7 8 9 7 2 3 1 2 0 5 3 2 1 0 Unit ft s m s m SIDE VIEW Vertical airflow direction louver Up Horizontal airflow direction louver Center m 0 1 2 3 4 5 6 7 8 9 7 2 3 1 2 0 5 3 2 1 0 Unit ft s m s m SIDE VIEW Vertical airflow direction louver Down Horizontal airflow direction louver Center m...

Страница 12: ...mber of rotations r p m Air flow HIGH 1320 m3 h 750 l s 208 CFM 441 MED 1160 m3 h 640 l s 178 CFM 376 LOW 930 m3 h 480 l s 133 CFM 282 QUIET 680 m3 h 310 l s 86 CFM 182 Fan speed Number of rotations r p m Air flow HIGH 1320 m3 h 750 l s 208 CFM 441 MED 1160 m3 h 640 l s 178 CFM 376 LOW 980 m3 h 520 l s 144 CFM 306 QUIET 710 m3 h 330 l s 92 CFM 194 ...

Страница 13: ...50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 Octave band center frequency Hz 80 70 60 50 40 30 20 10 0 63 125 250 500 1 000 2 000 4 000 8 000 Octave band center frequency Hz 80 70 60 50 40 30 20 10 0 63 125 250 500 1 000 2 000 4 000 8 000 High Quiet High Quiet Octave band sound pressure level dB 0 dB 0 0002 µbar Octave band center frequency Hz 80 70 60 50 40 30 20 10 0 63 125 250 500 1 000 2 000 4...

Страница 14: ... 01 11 WALL MOUNTED TYPE RIWH09 12AVFJ WALL MOUNTED TYPE RIWH09 12AVFJ 6 2 SOUND LEVEL CHECK POINT 32in 0 8m 40in 1m ...

Страница 15: ...ICS Model name RIWH09AVFJ RIWH12AVFJ Power supply Voltage V 208 230 Frequency Hz 60 Max operating current A 0 4 Wiring spec 1 Connection cable AWG 14 Limited wiring length ft m 68 21 1 Wiring specification Selected sample Selected based on Japan Electrotechnical Standards and Codes Committee E0005 ...

Страница 16: ...VFJ WALL MOUNTED TYPE RIWH09 12AVFJ 8 SAFETY DEVICES Protection form Model RIWH09AVFJ RIWH12AVFJ Circuit protection Current fuse PC board 250V 3 15A Fan motor protection Thermal protector program OFF 221 18 F 105 10 C ON 194 18 F 90 10 C ...

Страница 17: ...tor on the external control PC board and turning it ON Unit operation Initial setting after power is ON Starting mode other than initial setting Operation mode Auto changeover Mode at previous operation Set temperature 75 F 24 C Temperature at previous operation Air flow mode AUTO Mode at previous operation Air direction swing Standard air direction swing OFF Air direction at previous operation z ...

Страница 18: ... signal ON OFF Indoor unit Operation Stop Command Forced stop Normal Remote control operation invalidity z zParts Optional Parts name Model name External connect kit RXXWZXZ5 Communication kit RXXCBXZ2 For operating the EXTERNAL function the wall mounted type requires the communication kit in addition to the wire RXXWZXZ5 Wire External input RXXWZXZ5 ...

Страница 19: ...0 mA to less than 500 mA Ex Display Indoor unit control PC board Communication kit Connected unit Ex Relay unit 1 2 Signal Relay power supply V Connector 33ft 10m 24V DC Optional parts Locally purchased ON OFF Operation Stop Indoor unit Output signal z zParts Optional Parts name Model name External connect kit RXXWZXZ5 Communication kit RXXCBXZ2 For operating the EXTERNAL function the wall mounted...

Страница 20: ...han 500 mA z zParts Optional Parts name Model name External connect kit RXXWZXZ5 Communication kit RXXCBXZ2 For operating the EXTERNAL function the wall mounted type requires the communication kit in addition to the wire RXXWZXZ5 Wire External output RXXWZXZ5 Ex Display Indoor unit control PC board Communication kit Connected unit Ex Relay unit 1 2 Signal Relay power supply V Connector 33ft 10m 24...

Страница 21: ...nel To facilitate explanation the accompanying illustration has been drawn to show all possible indicators in actual operation however the display will only show those indicators appropriate to the current operation Mode indicator Clock Timer indicator Send indicator Temperature indicator Transmit indicator Fan Speed indicator Swing indicator SPECIFICATION NOTE Some button operations may not be av...

Страница 22: ...TING 1 Press the SET TEMP button to change the custom code between Match the code on the display to the air conditioner custom code initially set to If the custom code does not need to be selected press the MIN HEAT button and proceed to STEP 2 2 Press the MODE button and check that the indoor unit can receive signals at the displayed custom code 3 Press the MIN HEAT button to accept the custom co...

Страница 23: ...01 Long interval 1000 hours 02 Short interval 200 hours 03 No indication 2 Room temperature control for indoor unit sensor Refer to Function 95 before performing this setting Depending on the installed environment correction of the room temperature sensor may be required Select the appropriate control setting according to the installed environment The temperature correction values show the differe...

Страница 24: ...Sensors on both indoor unit and wired remote controller are active Remote controller sensor must be turned on by using the remote controller 5 Remote controller custom code Only for wireless remote controller The indoor unit custom code can be changed Select the appropriate custom code Factory setting Function number Setting value Setting description 44 00 A 01 B 02 C 03 D 6 External input control...

Страница 25: ...ting description 92 For cooling 93 For heating 00 No correction 0 0 F 0 0 C 01 No correction 0 0 F 0 0 C 02 1 F 0 5 C More Cooling Less Heating 03 2 F 1 0 C 04 3 F 1 5 C 05 4 F 2 0 C 06 5 F 2 5 C 07 6 F 3 0 C 08 7 F 3 5 C 09 8 F 4 0 C 10 1 F 0 5 C Less Cooling More Heating 11 2 F 1 0 C 12 3 F 1 5 C 13 4 F 2 0 C 14 5 F 2 5 C 15 6 F 3 0 C 16 7 F 3 5 C 17 8 F 4 0 C 10 Heat Insulation condition buildi...

Страница 26: ...e 4 Press the MODE button again to return to the clock display The custom code will be changed If no buttons are pressed within 30 seconds after the custom code is displayed the system returns to the original clock display In this case start again from step 1 The air conditioner custom code is set to A prior to shipment The remote controller resets to custom code A when the batteries in the remote...

Страница 27: ... room temperature can be controlled by detecting the temperature accurately with built in thermo sensor Optional communication kit is necessary for installation Simple remote controller RXRSNUM Compact remote controller concentrates on the basic functions such as Start Stop Fan Control Temperature Setting and Operation mode Optional communication kit is necessary for installation Exterior Parts na...

Страница 28: ...2 OUTDOOR UNIT SINGLE TYPE ROSH09AFWJ ROSH12AFWJ DTR_AO230E_01 2017 01 27 ...

Страница 29: ...ERANT CIRCUIT 02 04 4 WIRING DIAGRAMS 02 06 5 CAPACITY COMPENSATION RATE FOR PIPE LENGTH AND HEIGHT DIFFERENCE 02 08 6 ADDITIONAL CHARGE CALCULATION 02 10 7 AIR FLOW 02 11 8 OPERATION NOISE 02 12 8 1 NOISE LEVEL CURVE SOUND PRESSURE 02 12 8 2 SOUND LEVEL CHECK POINT 02 13 9 ELECTRIC CHARACTERISTICS 02 14 10 SAFETY DEVICES 02 15 ...

Страница 30: ...gerant oil Type RB68 VG74 Enclosure Material Steel Color Beige Approximate color of MUNSELL 10YR7 5 1 0 Dimensions H W D Net mm 540 660 290 540 790 290 in 21 1 4 26 11 7 16 21 1 4 31 1 8 11 7 16 Gross mm 611 797 401 648 934 400 in 24 1 16 31 3 8 15 13 16 25 1 2 36 3 4 15 3 4 Weight Net lb kg 60 27 80 36 Gross 67 30 86 39 Connenction pipe Size Liquid in mm Ø1 4 Ø6 35 Gas Ø3 8 Ø9 52 Method Flare Pre...

Страница 31: ...the front and left side 24 600 or more 4 100 or more 8 200 or more 4 100 or more 10 250 or more Service space CAUTION When the outdoor temperature is 32 F 0 C or less do not use the accessory drain pipe and drain cap If the drain pipe and drain cap are used the drain water in the pipe may freeze in extremely cold weather Reverse cycle model only In areas with heavy snowfall if the intake and outle...

Страница 32: ...ront and left side 24 600 or more 4 100 or more 8 200 or more 4 100 or more 10 250 or more Service space CAUTION When the outdoor temperature is 32 F 0 C or less do not use the accessory drain pipe and drain cap If the drain pipe and drain cap are used the drain water in the pipe may freeze in extremely cold weather Reverse cycle model only In areas with heavy snowfall if the intake and outlet of ...

Страница 33: ... 02 04 OUTDOOR UNIT ROSH09 12AFWJ OUTDOOR UNIT ROSH09 12AFWJ 3 REFRIGERANT CIRCUIT MODEL ROSH09AFWJ ...

Страница 34: ... 02 05 OUTDOOR UNIT ROSH09 12AFWJ OUTDOOR UNIT ROSH09 12AFWJ MODEL ROSH12AFWJ ...

Страница 35: ... 02 06 OUTDOOR UNIT ROSH09 12AFWJ OUTDOOR UNIT ROSH09 12AFWJ 4 WIRING DIAGRAMS MODEL ROSH09AFWJ ...

Страница 36: ... 02 07 OUTDOOR UNIT ROSH09 12AFWJ OUTDOOR UNIT ROSH09 12AFWJ MODEL ROSH12AFWJ ...

Страница 37: ...ft 0 979 0 965 0 890 0 929 5m 16ft 0 992 0 983 0 969 0 893 0 933 0m 0ft 1 000 0 991 0 976 0 901 0 940 Ú2 Indoor unit is lower than outdoor unit 5m 16ft 1 000 0 991 0 976 0 901 0 940 7 5m 25ft 0 991 0 976 0 901 0 940 10m 33ft 0 976 0 901 0 940 15m 49ft 0 901 0 940 HEATING Pipe length 5m 7 5m 10m 15m 20m 16ft 25ft 33ft 49ft 66ft Height difference H Ú1 Indoor unit is higher than outdoor unit 15m 49ft...

Страница 38: ...t 0 992 0 964 0 937 0 879 0 889 0m 0ft 1 000 0 972 0 944 0 887 0 896 Ú2 Indoor unit is lower than outdoor unit 5m 16ft 1 000 0 972 0 944 0 887 0 896 7 5m 25ft 0 972 0 944 0 887 0 896 10m 33ft 0 944 0 887 0 896 15m 49ft 0 887 0 896 HEATING Pipe length 5m 7 5m 10m 15m 20m 16ft 25ft 33ft 49ft 66ft Height difference H Ú1 Indoor unit is higher than outdoor unit 15m 49ft 0 896 0 879 10m 33ft 0 968 0 890...

Страница 39: ...zREFRIGERANT CHARGE Refrigerant type R410A Refrigerant amount lb oz 1lb 14oz g 850 Pipe length ft 49 or less 66 MAX 0 22oz ft 20g m m 15 or less 20 MAX Additional charge oz 0 3 5 g 0 100 Refrigerant type R410A Refrigerant amount lb oz 2lb 5oz g 1050 Pipe length ft 49 or less 66 MAX 0 22oz ft 20g m m 15 or less 20 MAX Additional charge oz 0 3 5 g 0 100 ...

Страница 40: ...eating MODEL ROSH12AFWJ z zCooling z zHeating Number of rotations r p m Air flow 780 1690 m3 h 469 l s 995 CFM Number of rotations r p m Air flow 720 1540 m3 h 428 l s 906 CFM Number of rotations r p m Air flow 780 1760 m3 h 489 l s 1036 CFM Number of rotations r p m Air flow 680 1510 m3 h 419 l s 889 CFM ...

Страница 41: ...ve band center frequency Hz 80 70 60 50 40 30 20 10 0 63 125 250 500 1 000 2 000 4 000 8 000 NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 z zHeating Octave band sound pressure level dB 0dB 0 0002µbar Octave band center frequency Hz 80 70 60 50 40 30 20 10 0 63 125 250 500 1 000 2 000 4 000 8 000 NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 Octave band soun...

Страница 42: ... 02 13 OUTDOOR UNIT ROSH09 12AFWJ OUTDOOR UNIT ROSH09 12AFWJ 8 2 SOUND LEVEL CHECK POINT 40 in 1m ...

Страница 43: ...er Supply Voltage V 208 230 Frequency Hz 60 MCA A 10 12 Starting Current A 4 2 5 9 1 Wiring Spec MAX CKT BKR A 15 20 Power Cable AWG 14 1 Wiring Spec Selected Sample Selected based on Japan Electrotechnical Standard and Codes Committee E00005 MCA Min Circuit Amp Calculation based on UL1995 MAX CKT BKR Maximum Circuit Breaker ...

Страница 44: ...urrent fuse IN THE INVERTER CASE 250V 20A 250V 5A Current fuse MAIN PRINTED CIRCUIT BOARD 250V 15A 250V 3 15A Fan motor protection Terminal protection program OFF 212 27 F 100 15 C ON 203 18 F 95 10 C OFF 302 27 F 150 15 C ON 230 18 F 120 15 C Compressor protection Terminal protection program COMPRESSOR TEMP OFF 230 F 110 C ON After 7 minutes ...