9. EXTERNAL INPUT & OUTPUT
Connector
INPUT
OUTPUT
REMARKS
CNA01
Control input
-
See external
input/output settings
for details.
CNB01
-
Operation status output
CNB02
-
Error status output
9-1. EXTERNAL INPUT
CONTROL INPUT (Operation/Stop or Forced stop)
The air conditioner can be remotely operated by means of the following on-site work.
"Operation/Stop" mode or "Forced stop" mode can be selected with function setting of indoor unit.
Unit operation is started at the following contents by adding the contact input of a commercial ON/OFF switch to a
connector on the external control PC board and turning it ON.
Unit operation
Initial setting after power is ON
Starting mode other than initial setting
Operation mode
Auto changeover
Mode at previous operation
Set temperature
75°F (24°C)
Temperature at previous operation
Air flow mode
AUTO
Mode at previous operation
Air direction (swing)
Standard air direction (swing OFF)
Air direction at previous operation
z
Circuit diagram example
Signal
Locally purchased
Indoor unit
control PC board
Communication kit
Optional parts
Connector
1
3
*33ft. (10m)
Connected unit
Ex.) Switch
* Make the distance from the PC board to the connected unit within 33ft. (10m).
Contact capacity: DC 24 V or more, 10 mA or more.
Use non-polar relays and switches.
z
When function setting is in "Operation/Stop" mode
Operation
Stop
ON
OFF
Input signal
Indoor unit
Содержание RIWH09AVFJ
Страница 2: ...1 INDOOR UNIT WALL MOUNTED TYPE RIWH09AVFJ RIWH12AVFJ DTR_AS129E_01 2017 01 27 ...
Страница 28: ...2 OUTDOOR UNIT SINGLE TYPE ROSH09AFWJ ROSH12AFWJ DTR_AO230E_01 2017 01 27 ...
Страница 33: ... 02 04 OUTDOOR UNIT ROSH09 12AFWJ OUTDOOR UNIT ROSH09 12AFWJ 3 REFRIGERANT CIRCUIT MODEL ROSH09AFWJ ...
Страница 34: ... 02 05 OUTDOOR UNIT ROSH09 12AFWJ OUTDOOR UNIT ROSH09 12AFWJ MODEL ROSH12AFWJ ...
Страница 35: ... 02 06 OUTDOOR UNIT ROSH09 12AFWJ OUTDOOR UNIT ROSH09 12AFWJ 4 WIRING DIAGRAMS MODEL ROSH09AFWJ ...
Страница 36: ... 02 07 OUTDOOR UNIT ROSH09 12AFWJ OUTDOOR UNIT ROSH09 12AFWJ MODEL ROSH12AFWJ ...
Страница 42: ... 02 13 OUTDOOR UNIT ROSH09 12AFWJ OUTDOOR UNIT ROSH09 12AFWJ 8 2 SOUND LEVEL CHECK POINT 40 in 1m ...