Rheem RHS 32 Скачать руководство пользователя страница 18

18

FIG. 37

Cap

O-ring Seal

Screen Support

Screen

Gasket

*Flow Plug (HVDC)

Housing

Ferrule

Nut

Cone Screen

*Flow Plug

*Install with lettered

side up, concave

side down.

CLEANING THE NOZZLE & VENTURI

A clean nozzle & venturi (See Figure 37) is a necessity

for the water softener to work properly.  This small

component creates the suction to move brine from the

brine tank, into the resin tank.  If it should become

plugged with sand, silt, dirt, etc., the water softener will

not work, and hard water will result.

Nozzle & Venturi Disc

IMPORTANT: Be sure small hole in the gasket is cen-

tered directly over the small hole in the nozzle & ven-

turi housing.  Be sure the numbers are facing up

Routine Maintenance

To get access to the nozzle & venturi, remove the

water softener’s top cover.  Put the bypass valve(s)

into the bypass position.  Be sure the water softener is

in soft water (service) cycle (no water pressure at noz-

zle & venturi).  Then, holding the nozzle & venturi

housing with one hand, un screw the cap.  Do not lose

the o-ring seal.  Lift out the screen support and screen.

Then, remove the nozzle & venturi disc, gasket and

flow plug(s).  Wash the parts in warm, soapy water

and rinse in fresh water.  Be sure to clean both the top

and bottom of the nozzle & venturi disc.  If needed,

use a small brush to remove iron or dirt.  Do not

scratch, misshape, etc., surfaces of the nozzle & ven-

turi.
Gently replace all parts in the correct order.  Lubricate

the o-ring seal with silicone grease and locate in place.

Install and tighten the cap by hand, while supporting

the housing.  Overtightening may break the cap or

housing.  Put the bypass valve(s) into service (soft

water) position.
Recharge the softener to reduce water level in the

tank.  This will also assure that the softener is com-

pletely recharged and ready to provide softened water

again.  Check the water level in the tank by looking

down the brinewell.  If the water level does not drop

after a recharge, the problem has not been resolved.

Call 1-800-754-7027.

PROTECT THE WATER SOFTENER FROM

FREEZING

If the softener is installed where it could freeze (sum-

mer cabin, lake home, etc.), you must drain all water

from it to stop possible freeze damage.  To drain the

softener:

1

. Close the shut-off valve on the house main water

pipe, near the water meter or pressure tank.

2

. Open a faucet in the soft water pipes to vent pres-

sure in the softener.

3

. Move the stem in the single bypass valve to bypass.

Close the inlet and outlet valve in a 3 valve bypass

system, and open the bypass valve.  If you want

water in the house pipes again, reopen the shut-off

valve on the main water pipe.

4

. Unplug the power supply at the wall outlet.  Remove

the softener’s top cover, together with the salt lid.

Take off both drain hoses if they will interfere with

moving the softener into position over the drain.

5

. Carefully remove the large holding clips at the sof-

tener inlet and outlet.  Separate the softener from

the plastic installation adaptors, or from the bypass

valve.

6

. Lay a piece of 2 inch thick board near the floor drain

(See Figure 38).

7

. Move the softener close to the drain.  Slowly and

gently, tip it over until the rim rests on the wood

block with the inlet and outlet over the drain.  Do not

allow the softener’s weight to rest on the inlet and

outlet fittings or they may break.

8

. Tip the bottom of the softener up a few inches and

hold until all water has drained.  Leave the softener

laying like this until you are ready to use it.  Plug the

inlet and outlet with clean rags to keep dirt, bugs,

etc. out.

Floor Drain

FIG. 38

Wood Block

Содержание RHS 32

Страница 1: ...1 10 20 If you have any questions or concerns when installing operating or maintaining your water softener call our toll free number 1 800 754 7027 or visit www rheemwatertreatment com When you call p...

Страница 2: ...7 Installation Instructions 8 11 Programming the Water Softener 12 14 Customizing Features 15 16 Routine Maintenance 17 18 Troubleshooting 19 21 Exploded View Parts List 22 25 Warranty 26 Dimensions 3...

Страница 3: ...apacity and efficiency Continuous operation at flow rates greater than the service flow rate may affect capacity and efficiency performance Capacity to reduce clear water iron is substantiated by labo...

Страница 4: ...t breaker or fuse Do not use this system to treat water that is microbiologically unsafe or of unknown quality without adequate dis infection upstream or downstream of the system European Directive 20...

Страница 5: ...the water stands for a period of time the particles settle to the bottom of the container Generally these irons are removed from water by filtra tion Chlorination is also recommended for bacterial ir...

Страница 6: ...r softener works on 24V DC electrical power supplied by a direct plug in power supply included Provide nearby a 120V 60 Hz electrical outlet in accordance with NEC and local codes Always install the w...

Страница 7: ...2 O D Tube not included Cut barbs from drain fit ting pull clip to remove fitting from valve FIG 7 FIG 8 SINGLE BYPASS VALVE Pull out for Service Soft water Push in for Bypass 3 VALVE BYPASS From Wat...

Страница 8: ...d salt may cause the tank to fracture at the shim 2 Visually check and remove any debris from the water softener valve inlet and outlet ports Carefully remove the two large plastic clips you will use...

Страница 9: ...rts of the water softener valve Be sure to keep fittings fully together and pipes squared and straight Be sure hard water supply pipe goes to the water sof tener valve inlet side NOTE Inlet and outlet...

Страница 10: ...the main water supply valve Run water until there is a steady flow from the opened faucets with no air bubbles 4 Place bypass valve s in service or soft water posi tion as follows Single bypass valve...

Страница 11: ...ia could get into the unit For this reason sanitizing as follows is suggested when installing 1 Slide open the salt lid remove the brinewell cover and pour about 3 oz 6 tablespoons of household bleach...

Страница 12: ...splay ahead down sets the time back NOTE Press buttons and quickly release to slowly advance the display Hold the buttons down for fast advance 2 When the correct time is displayed press the SELECT bu...

Страница 13: ...DOWN buttons to change the time in 1 hour increments Be sure AM or PM is correct 2 When the desired recharge start time is displayed press the SELECT button and the display will change to show one of...

Страница 14: ...esired Even if the clock is incorrect after a long power outage the softener works as it should to keep your water soft however regenera tions may occur at the wrong time of day until you reset the cl...

Страница 15: ...ate of California you MUST turn the efficiency feature ON The softener may initiate more frequent recharges but it will operate at 4000 grains per pound of salt or higher 12 OR 24 HOUR CLOCK All time...

Страница 16: ...mes in 1 minute increments If you wish to increase the backwash time use the r UP or s DOWN buttons to add up to 15 min utes Then press the OK button to display the fast rinse time Add screen If you w...

Страница 17: ...idge Carefully push into the bridge in several places to break it Do not use any sharp or pointed objects as you may puncture the brine tank Do not try to break the salt bridge by pounding on the out...

Страница 18: ...water level in the tank This will also assure that the softener is com pletely recharged and ready to provide softened water again Check the water level in the tank by looking down the brinewell If t...

Страница 19: ...ce Brine Valve Float Assembly 7 Leak between valve and resin tank Replace o rings between resin tank and valve Water hard some times 1 Incorrect time set Check and change time setting 2 Incorrect wate...

Страница 20: ...ration NOTE Be sure water is in contact with the salt and not separated by a salt bridge See Breaking A Salt Bridge section 5 While in this diagnostic screen the following information is available and...

Страница 21: ...4 Press the RECHARGE button to move the soften er s valve into the fast rinse position Again look for a fast drain flow Allow the softener to rinse for a few minutes to flush out any brine that may r...

Страница 22: ...22 Softener Exploded View 8 7 6 5 29 28 30 14 15 12 21 24 10 23 25 26 27 7 5 3 8 9 6 Valve Assembly See Pages 24 25 for parts 4 2 1 22 20 17 18 19 13 11 16...

Страница 23: ...y Nos 21 23 21 Wing Nut 1 4 20 22 Spacer 3 4 long 23 Screw 1 4 20 x 1 1 2 24 7213475 Brinewell 7331258 Overflow Hose Adaptor Kit includes Key Nos 25 27 25 Adaptor Elbow 26 Grommet 27 Hose Clamp 28 731...

Страница 24: ...24 Valve Exploded View 50 52 53 51 55 56 59 58 57 60 61 66 67 62 63 64 68 69 70 71 75 65 Wear Strip Seal Cross section View 90 91 92 54 72 73 74 76 78 80 77 79 83 85 86 87 88 89 81 82 84...

Страница 25: ...bine Support Assembly including 2 O Rings See Key No 72 1 ea of Key Nos 73 74 73 Turbine Support Shaft 74 Turbine 75 7082053 Valve Body 76 7081201 Retainer Nozzle Venturi 77 7342649 O Ring 1 4 x 3 8 p...

Страница 26: ...the result of strikes government regulation materials shortages or other circumstances beyond its control THERE ARE NO WARRANTIES ON THE WATER SOFTENER BEYOND THOSE SPECIFICALLY DESCRIBED ABOVE ALL IM...

Отзывы: