Programming the Water Softener

FIG. 25

Questions? Call Toll Free 1-800-754-7027

or visit

www.rheemwatertreatment.com

When you call, please be prepared to provide the model and serial number,

found on the rating decal inside the salt lid.

FIG. 26

FIG. 27

continued from previous page

2

. The salt level scale, on the brinewell inside the

tank, has numbers from 0 to 8 (See Fig. 24).

Observe the highest number the leveled salt is at,

or closest to.

3

. Press the 

r

UP or 

s

DOWN buttons until the

number on the screen corresponds to the salt level.

At level 2 or below, the status light will flash.  If you

wish to turn this feature off, press the 

s

DOWN

button past 0, and the word “OFF” flashes in the

display.

4

. Press the SELECT button once more to complete

the initial programming.  The current time of day

will show in the display.

PROGRAM MEMORY

If electrical power to the softener goes off, the time

display is blank but the electronic controller keeps the

correct time for several hours.  When electrical power

comes on again, you will have to reset the present

time only if the display is flashing.  The HARDNESS

and RECHARGE TIME never require resetting unless

a change is desired.  Even if the clock is incorrect

after a long power outage, the softener works as it

should to keep your water soft, however, regenera-

tions may occur at the wrong time of day until you

reset the clock to the correct time of day.

EXTRA RECHARGE

Sometimes, a manually initiated recharge (regenera-

tion) may be desired, or needed.  Two examples are:

=

You have used more water than usual (guests visit-

ing) and you may run out of soft water before the

next automatic regeneration.

=

You did not add salt to the softener before it ran

out.  Add salt to the softener before regenerating.

You can start a regeneration immediately, or you can

set the controller to regenerate at the next preset

recharge time (2:00 AM, or as set).

RECHARGE NOW

Press the RECHARGE button and hold for 3 sec-

onds, until the words “RECHARGE NOW” begin to

flash in the display.  The softener enters the fill cycle

of regeneration immediately.  This regeneration will

take about 2 hours to complete.  Then, you will have

soft water again.

RECHARGE TONIGHT

Press and release (do not hold) the RECHARGE but-

ton.  “RECHARGE TONIGHT” will begin flashing in

the display, and the softener will begin regeneration

at the next preset recharge time (2:00 AM, or as set).

If you decide to cancel the regeneration before it

starts, press and release the RECHARGE button

once more.  “RECHARGE TONIGHT” will stop flash-

ing in the display.

Содержание RHS 32

Страница 1: ...1 10 20 If you have any questions or concerns when installing operating or maintaining your water softener call our toll free number 1 800 754 7027 or visit www rheemwatertreatment com When you call p...

Страница 2: ...7 Installation Instructions 8 11 Programming the Water Softener 12 14 Customizing Features 15 16 Routine Maintenance 17 18 Troubleshooting 19 21 Exploded View Parts List 22 25 Warranty 26 Dimensions 3...

Страница 3: ...apacity and efficiency Continuous operation at flow rates greater than the service flow rate may affect capacity and efficiency performance Capacity to reduce clear water iron is substantiated by labo...

Страница 4: ...t breaker or fuse Do not use this system to treat water that is microbiologically unsafe or of unknown quality without adequate dis infection upstream or downstream of the system European Directive 20...

Страница 5: ...the water stands for a period of time the particles settle to the bottom of the container Generally these irons are removed from water by filtra tion Chlorination is also recommended for bacterial ir...

Страница 6: ...r softener works on 24V DC electrical power supplied by a direct plug in power supply included Provide nearby a 120V 60 Hz electrical outlet in accordance with NEC and local codes Always install the w...

Страница 7: ...2 O D Tube not included Cut barbs from drain fit ting pull clip to remove fitting from valve FIG 7 FIG 8 SINGLE BYPASS VALVE Pull out for Service Soft water Push in for Bypass 3 VALVE BYPASS From Wat...

Страница 8: ...d salt may cause the tank to fracture at the shim 2 Visually check and remove any debris from the water softener valve inlet and outlet ports Carefully remove the two large plastic clips you will use...

Страница 9: ...rts of the water softener valve Be sure to keep fittings fully together and pipes squared and straight Be sure hard water supply pipe goes to the water sof tener valve inlet side NOTE Inlet and outlet...

Страница 10: ...the main water supply valve Run water until there is a steady flow from the opened faucets with no air bubbles 4 Place bypass valve s in service or soft water posi tion as follows Single bypass valve...

Страница 11: ...ia could get into the unit For this reason sanitizing as follows is suggested when installing 1 Slide open the salt lid remove the brinewell cover and pour about 3 oz 6 tablespoons of household bleach...

Страница 12: ...splay ahead down sets the time back NOTE Press buttons and quickly release to slowly advance the display Hold the buttons down for fast advance 2 When the correct time is displayed press the SELECT bu...

Страница 13: ...DOWN buttons to change the time in 1 hour increments Be sure AM or PM is correct 2 When the desired recharge start time is displayed press the SELECT button and the display will change to show one of...

Страница 14: ...esired Even if the clock is incorrect after a long power outage the softener works as it should to keep your water soft however regenera tions may occur at the wrong time of day until you reset the cl...

Страница 15: ...ate of California you MUST turn the efficiency feature ON The softener may initiate more frequent recharges but it will operate at 4000 grains per pound of salt or higher 12 OR 24 HOUR CLOCK All time...

Страница 16: ...mes in 1 minute increments If you wish to increase the backwash time use the r UP or s DOWN buttons to add up to 15 min utes Then press the OK button to display the fast rinse time Add screen If you w...

Страница 17: ...idge Carefully push into the bridge in several places to break it Do not use any sharp or pointed objects as you may puncture the brine tank Do not try to break the salt bridge by pounding on the out...

Страница 18: ...water level in the tank This will also assure that the softener is com pletely recharged and ready to provide softened water again Check the water level in the tank by looking down the brinewell If t...

Страница 19: ...ce Brine Valve Float Assembly 7 Leak between valve and resin tank Replace o rings between resin tank and valve Water hard some times 1 Incorrect time set Check and change time setting 2 Incorrect wate...

Страница 20: ...ration NOTE Be sure water is in contact with the salt and not separated by a salt bridge See Breaking A Salt Bridge section 5 While in this diagnostic screen the following information is available and...

Страница 21: ...4 Press the RECHARGE button to move the soften er s valve into the fast rinse position Again look for a fast drain flow Allow the softener to rinse for a few minutes to flush out any brine that may r...

Страница 22: ...22 Softener Exploded View 8 7 6 5 29 28 30 14 15 12 21 24 10 23 25 26 27 7 5 3 8 9 6 Valve Assembly See Pages 24 25 for parts 4 2 1 22 20 17 18 19 13 11 16...

Страница 23: ...y Nos 21 23 21 Wing Nut 1 4 20 22 Spacer 3 4 long 23 Screw 1 4 20 x 1 1 2 24 7213475 Brinewell 7331258 Overflow Hose Adaptor Kit includes Key Nos 25 27 25 Adaptor Elbow 26 Grommet 27 Hose Clamp 28 731...

Страница 24: ...24 Valve Exploded View 50 52 53 51 55 56 59 58 57 60 61 66 67 62 63 64 68 69 70 71 75 65 Wear Strip Seal Cross section View 90 91 92 54 72 73 74 76 78 80 77 79 83 85 86 87 88 89 81 82 84...

Страница 25: ...bine Support Assembly including 2 O Rings See Key No 72 1 ea of Key Nos 73 74 73 Turbine Support Shaft 74 Turbine 75 7082053 Valve Body 76 7081201 Retainer Nozzle Venturi 77 7342649 O Ring 1 4 x 3 8 p...

Страница 26: ...the result of strikes government regulation materials shortages or other circumstances beyond its control THERE ARE NO WARRANTIES ON THE WATER SOFTENER BEYOND THOSE SPECIFICALLY DESCRIBED ABOVE ALL IM...

Отзывы: